A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automated regional citrate anticoagulation based on online monitoring of ionized calcium concentration: Proof of concept. | LitMetric

Automated regional citrate anticoagulation based on online monitoring of ionized calcium concentration: Proof of concept.

Artif Organs

Division of Nephrology & Critical Care Nephrology Unit, Shanghai Ninth People's Hospital, Shanghai JiaoTong University, School of Medicine, Shanghai, China.

Published: November 2022

Background: Regional citrate anticoagulation (RCA), a complex and effective technique, is recommended as the anticoagulation of choice for continuous renal replacement therapy. One of its key objectives is to keep the ionized calcium in the targeted range. In this study, we aimed to develop an automated RCA based on online monitoring of the ionized calcium concentration and closed-loop feedback.

Methods: We constructed calcium-selective electrodes with liquid inner contact, which measured a potentiometric signal as the output. We tested the responses, stability, and selectivity of the electrodes in flowing fluid containing calcium chloride. We compared the measurement accuracy between the electrodes and an i-STAT system in vivo. Moreover, we established closed-loop feedback using a proportional-integral-derivative controller model. We performed simulated automated RCA both in vivo and in vitro.

Results: The electrode gave a Nernstian response to the variation of ionized calcium concentration. It showed high stability and a relatively short response time. Changes in the fluid flow rate, solution PH, and addition of metal ions including Mg and K did not interfere with the measurements of ionized calcium. These measurements in whole blood by the electrode were very close to those assessed by the i-STAT system. The feedback control system responded quickly to an abnormal ionized calcium concentration and regulated the infusion rates of calcium or citrate to maintain the concentration of ionized calcium within the targeted range.

Conclusions: We successfully trialed automated RCA, which may help simplify the complexities of RCA in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aor.14335DOI Listing

Publication Analysis

Top Keywords

ionized calcium
28
calcium concentration
16
automated rca
12
calcium
9
regional citrate
8
citrate anticoagulation
8
based online
8
online monitoring
8
monitoring ionized
8
calcium targeted
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!