A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Modeling and simulation of high energy density lithium-ion battery for multiple fault detection. | LitMetric

Lithium-ion battery, a high energy density storage device has extensive applications in electrical and electronic gadgets, computers, hybrid electric vehicles, and electric vehicles. This paper presents multiple fault detection of lithium-ion battery using two non-linear Kalman filters. A discrete non-linear mathematical model of lithium ion battery has been developed and Unscented Kalman filter (UKF) is employed to estimate the model parameter. Occurrences of multiple faults such as over-charge, over-discharge and short circuit faults between inter cell power batteries, affects the parameter variation of system model. Parallel combinations of some UKF (bank of filters) compare the model parameter variation between the normal and faulty situation and generates residual signal indicating different fault. Simulation results of multiple numbers of statistical tests have been performed for residual based fault diagnosis and threshold calculation. The performance of UKF is then compared with Extended Kalman filter (EKF) with same battery model and fault scenario. The simulation result proves that UKF model responses better and quicker than that of EKF for fault diagnosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9192780PMC
http://dx.doi.org/10.1038/s41598-022-13771-4DOI Listing

Publication Analysis

Top Keywords

lithium-ion battery
12
high energy
8
energy density
8
multiple fault
8
fault detection
8
detection lithium-ion
8
electric vehicles
8
kalman filter
8
model parameter
8
parameter variation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!