Background And Aims: Endoscopic suturing and over-the-scope clips (OTSCs) are used to prevent migration of fully covered self-expandable metal stents (FCSEMSs). Recently, a dedicated OTSC was developed for securing FCSEMSs. Our primary aim was to compare the frequency of stent migration without stent fixation versus fixation with suturing or OTSCs, and out secondary aims were to compare clinical success, procedure duration, and adverse events.
Methods: A retrospective cohort study evaluated the outcome of stent placement throughout the entire GI tract from 2013 to 2021. Stent migration was determined as stent displacement ≥2 cm endoscopically or radiographically. Clinical success was defined as resolution of indication at follow-up.
Results: Four hundred thirty-three procedures were performed, 239 (55%) without fixation, 140 (32%) with suturing, and 54 (12%) with OTSCs. Stent migration rates were 62% without fixation, 57% with suturing, and 35% with OTSCs (P = .013). The median time to stent migration was 3 weeks without fixation, 5 weeks with suturing, and 6 weeks with OTSCs (P = .023). The clinical success rate was 43%. The median procedure time for OTSCs was shorter compared with suturing (42 vs 68 minutes, P = .002). Adverse event rates trended toward being lowest with OTSCs at 9% compared with 21% without fixation and 18% with suturing (P > .05).
Conclusions: OTSCs for stent fixation were found to have significantly lower migration rates compared with no fixation and suturing. Moreover, OTSCs were associated with decreased overall procedure time and total costs per procedure while trending to be associated with fewer adverse events.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.gie.2022.06.001 | DOI Listing |
J Vasc Surg Cases Innov Tech
April 2025
Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
This report details the case of an 84-year-old male with an infrarenal abdominal aortic aneurysm and a dilated right common iliac artery eligible for endovascular treatment. A bifurcated stent graft (Medtronic Endurant IIs) was used to treat the aneurysm. To address the concerns of instability of the right iliac limb, four endoanchors (Heli-FX EndoAnchor, Medtronic) were placed at the distal landing zone to provide additional fixation.
View Article and Find Full Text PDFJ Vis Exp
December 2024
Department of General Surgery (Hepatobiliary, Pancreatic and Splenic Surgery), The Sixth Affiliated Hospital, Sun Yat-sen University; Biomedical Innovation Center, The Sixth Affiliated Hospital, Sun Yat-sen University;
Robot-assisted pancreaticobiliary junction resection is a surgical technique employed to treat benign duodenal tumors. The procedure involves several key steps: making a longitudinal incision in the duodenum, excising the tumor at the pancreaticobiliary junction, inserting a biliary stent, connecting the biliary and duodenal mucosa, and suturing the duodenal incision during phase I. The robotic system enhances visibility, facilitates precise operations, minimizes duodenal traction injuries to the duodenum and surgical trauma, ensures accurate suture and fixation of bile duct stents, connects the bile duct and duodenal mucosa and reduces postoperative recovery time.
View Article and Find Full Text PDFJ Pediatr Urol
December 2024
Departament of Urology, CACAU-NUPEP, São Paulo, Brazil. Electronic address:
Pyeloplasty at an early age (<2 years) can be treated by a flank open, laparoscopy or robotic approach. We want to demonstrate our strategy and how to construct a very inexpensive pyelostent from a Foley tube. The Ottoni catheter is made from a Foley tube, sectioning the proximal end keeping a plastic circular basement for fixation to the skin.
View Article and Find Full Text PDFGen Thorac Cardiovasc Surg Cases
December 2024
Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, Osaka, 564-8565, Japan.
Background: With the rapid expansion of transcatheter aortic valve replacement (TAVR), TAVR valve explantation is also increasing. Nevertheless, previous reports on Lotus Edge valve explantation are limited to only two reports, none of which include intraoperative videos. Therefore, we report the case of an older adult who underwent a 2-year-old Lotus Edge valve explantation, after developing prosthetic valve endocarditis (PVE) and aortic annular abscess, with a strong indication for a TAVR explantation and surgical aortic valve replacement (AVR).
View Article and Find Full Text PDFSpine Surg Relat Res
November 2024
Department of Orthopaedic Surgery, University of Tsukuba, Tsukuba, Japan.
Introduction: Percutaneous vertebral augmentation techniques, such as balloon kyphoplasty (BKP) and vertebral body stenting (VBS), are commonly used for surgical intervention in osteoporotic vertebral fractures (OVFs). However, markedly unstable OVF cases require additional fixation procedures, prompting the exploration of combined percutaneous vertebral augmentation and posterior fixation. A novel surgical approach involving percutaneous vertebral augmentation with upward penetrating endplate screws (PES) and downward PES, complemented by a short fusion of one above one below, was developed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!