CBCT Analysis of Prevalence of the Canalis Sinuosus on the Alveolar Ridge in the Site of Endosseous Implant Placement: A Retrospective Study.

J Long Term Eff Med Implants

Department of Implantology, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai 77, India.

Published: June 2022

This study aimed to perform a cone-beam computed tomography (CBCT) analysis in the Chennai population to check for the prevalence of the canalis sinuosus and its terminal branches in the site of endosseous implant placement in the alveolar ridge of the anterior maxilla. A retrospective analysis was conducted in Saveetha Dental College, Chennai. One hundred (50 male and 50 female) CBCT images that included the maxilla of patients aged 18-65 years were selected at random from the archives of the Oral Implantology Department, which were taken in the period from December 1, 2019 to November 30, 2020. Two examiners assessed all the scans with special training to identify this structure. The CBCTs were examined carefully for the presence of accessory canals and the side of occurrence, gender, relation in proximity to the anterior teeth (central incisors to the first premolar). The diameter of the canal was also noted as either less than 1 mm or greater than 1 mm. Our study showed that accessory canals of the canalis sinuous were identified in a total of 18 patients (4 female, 14 male). This shows that in our study, the prevalence of this structure amongst male patients was 14% and for female patients, it was 4%. This study shows that although the accessory canals of the canalis sinuous in the site of endosseous implant placement are rare, it must not be taken lightly because its occurrence still poses a significant risk of iatrogenic nerve damage, especially during implant placement procedures. In some individuals, the terminal branches of this canal or its accessory canals can sometimes be present in the site of placement of endosseous implants placed in the anterior maxilla. Lack of knowledge and awareness of this structure and the fact that its occurrence is often overlooked due to its rare occurrence causes the potential for iatrogenic damage to the nerve resulting in complications.

Download full-text PDF

Source
http://dx.doi.org/10.1615/JLongTermEffMedImplants.2022039656DOI Listing

Publication Analysis

Top Keywords

implant placement
16
accessory canals
16
site endosseous
12
endosseous implant
12
cbct analysis
8
prevalence canalis
8
canalis sinuosus
8
alveolar ridge
8
terminal branches
8
anterior maxilla
8

Similar Publications

Purpose: This study aimed to evaluate the impact of a metal artifact reduction (MAR) algorithm on cone-beam computed tomography (CBCT) scans of titanium and zirconia implants, both within and outside the field of view (FOV).

Materials And Methods: In this study, a dry human mandible was positioned in a CBCT scanner with only its left quadrant included in the FOV. Each type of implant (titanium and zirconia) was placed once in the right second premolar extraction socket and once in the left second premolar extraction socket of the mandible.

View Article and Find Full Text PDF

The submandibular displacement of a mandibular third molar residual root presents major challenges to oral and maxillofacial surgeons due to the proximity to critical anatomical structures such as the lingual nerve and sublingual artery. Preoperative imaging can approximate the location of the residual tooth root; however, accurately determining its exact position is difficult because of the dynamic nature of the mandible and the difficulty of real-time synchronization of imaging. This study presents the successful extraction of a residual mandibular third molar root in a 67-year-old female patient achieved using a magnetic field-based navigation system.

View Article and Find Full Text PDF

Objectives: The objective of this study was to evaluate the long-term clinical outcomes of one-piece narrow-diameter implants (NDIs), with diameters of 2.5 mm and 3.0 mm, and to investigate the factors that affect marginal bone loss (MBL) around these implants.

View Article and Find Full Text PDF

Background: Hemorrhage is a dangerous complication of deep brain stimulation (DBS) surgery, but a comprehensive explanation of the associated risk factors remains inconclusive, particularly application of microelectrode recording (MER) compared to macrostimulation (non-MER) based DBS procedures. We conducted a comparative analysis of MER and macrostimulation techniques, evaluating the impact of brain penetrations by microelectrode guiding cannulas on the occurrence of intracranial hemorrhagic events.

Methods: This retrospective study included all DBS procedures (MER-based and non-MER based) performed at a single medical center from November 2008 to June 2023.

View Article and Find Full Text PDF

Background: The present study aims to evaluate a three-dimensional (3D) changes in the crestal bone levels (buccally, lingually/palatally, mesially, and distally) and in the thickness of keratinized tissue around single or multiple implants using cone-beam computed tomography (CBCT) after 1 year.

Materials And Methods: Twenty-eight implants were placed in the posterior load-bearing areas in 10 patients. The crestal bone levels and the thickness of keratinized tissue surrounding the edentulous area were assessed preoperatively, immediately after implant placement, and 1 year after implant placement using CBCT (3D imaging technique with DICOM software (Carestream Health, Rochester, NY)).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!