A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of agreement between EXTEM and NATEM thromboelastometry measurement assays in critically ill neonates. | LitMetric

Objectives: To investigate the agreement between the EXTEM and NATEM measurements.

Methods: In this retrospective observational study, EXTEM and NATEM analyses were performed on blood samples from 162 ill neonates, providing 324 paired measurements. The agreement between EXTEM and NATEM measurements was evaluated by the nonparametric spearman's rank correlation to assess the correlation between the paired measurements, by the Bland-Altman analysis for the graphical presentation of the agreement, and by the Deming regression model to assess the significance of the agreement. The agreement between the two methods for the detection of bleeding events was determined by kappa statistic.

Results: Strong correlations were found between EXTEM and NATEM measurements for A10, MCF. The Bland-Altman plots showed good agreement for A10, MCF, LI60, and alpha angle parameters, while CT showed a nearly linear slope indicating that bias increased with the mean. The highest agreement for bleeding events was found for the A10 parameter (κ = 0.70, p < .001), while the lowest for the CT parameter (κ = 0.36, p = .94).

Conclusions: NATEM parameters that reflect clot firmness and fibrinolytic activity are strongly correlated with the corresponding EXTEM measurements with a good agreement between them, indicating that these two methods could be used interchangeably.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ejh.13812DOI Listing

Publication Analysis

Top Keywords

extem natem
20
agreement extem
12
ill neonates
8
paired measurements
8
natem measurements
8
bleeding events
8
a10 mcf
8
agreement
7
extem
5
natem
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!