A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and validation of a SYBR green-based mitochondrial DNA quantification method by following the MIQE and other guidelines. | LitMetric

In forensic mitochondrial DNA (mtDNA) analysis, quantitative PCR (qPCR) is usually performed to obtain high-quality sequence data for subsequent Sanger or massively parallel sequencing. Unlike methods for nuclear DNA quantification using qPCR, a calibrator is necessary to obtain mtDNA concentrations (i.e., copies/µL). Herein, we developed and validated a mtDNA quantification method based on a SYBR Green assay by following MIQE [Bustin et al., Clin. Chem. 55 (2009) 611-22] and other guidelines. Primers were designed to amplify nucleotide positions 16,190-16,420 in hypervariable region 1 for qPCR using PowerUp SYBR Green and QuantStudio 5. The optimized conditions were 0.3 µM each primer and an annealing temperature of 60 °C under a 2-step cycling protocol. K562 DNA at 100 pg/µL was converted into a mtDNA concentration of 16,400 copies/µL using linearized plasmid DNA. This mtDNA calibrator was obtained by cloning the synthesized DNA fragments of mtDNA (positions 16,140-16,470) containing a 100-bp inversion. The linear dynamic range of the K562 standard curve was 10,000-0.1 pg/µL (r ≥ 0.999). The accuracy was examined using NIST SRM 2372a, and its components A, B, and C were quantified with differences of -29.4%, -35.0%, and -22.0%, respectively, against the mtDNA concentrations calculated from published NIST data. We also examined the specificity of the primers, stability of the reaction mix, precision, tolerance against PCR inhibitors, and cross-reactivity against DNA from various animal taxa. Our newly developed mtDNA quantification method is expected to be useful for forensic mtDNA analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.legalmed.2022.102096DOI Listing

Publication Analysis

Top Keywords

quantification method
12
mtdna
9
mitochondrial dna
8
dna quantification
8
dna mtdna
8
mtdna analysis
8
mtdna concentrations
8
mtdna quantification
8
sybr green
8
dna
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!