A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Force and Torque Characterization in the Actuation of a Walking-Assistance, Cable-Driven Exosuit. | LitMetric

Force and Torque Characterization in the Actuation of a Walking-Assistance, Cable-Driven Exosuit.

Sensors (Basel)

Departamento de Ingeniería Mecánica, Energética y de los Materiales, Escuela de Ingenierías Industriales, Universidad de Extremadura, 06006 Badajoz, Spain.

Published: June 2022

Soft exosuits stand out when it comes to the development of walking-assistance devices thanks to both their higher degree of wearability, lower weight, and price compared to the bulkier equivalent rigid exoskeletons. In cable-driven exosuits, the acting force is driven by cables from the actuation system to the anchor points; thus, the user's movement is not restricted by a rigid structure. In this paper, a 3D inverse dynamics model is proposed and integrated with a model for a cable-driven actuation to predict the required motor torque and traction force in cables for a walking-assistance exosuit during gait. Joint torques are to be shared between the user and the exosuit for different design configurations, focusing on both hip and ankle assistance. The model is expected to guide the design of the exosuit regarding aspects such as the location of the anchor points, the cable system design, and the actuation units. An inverse dynamics analysis is performed using gait kinematic data from a public dataset to predict the cable forces and position of the exosuit during gait. The obtained joint reactions and cable forces are compared with those in the literature, and prove the model to be accurate and ready to be implemented in an exosuit control scheme. The results obtained in this study are similar to those found in the literature regarding the walking study itself as well as the forces under which cables operate during gait and the cable position cycle.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9185532PMC
http://dx.doi.org/10.3390/s22114309DOI Listing

Publication Analysis

Top Keywords

anchor points
8
inverse dynamics
8
exosuit gait
8
gait joint
8
cable forces
8
exosuit
6
force torque
4
torque characterization
4
actuation
4
characterization actuation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!