Many important biological processes such as protein folding and ligand binding are too fast to be fully resolved using conventional stopped-flow techniques. Although advances in mixer design and detection methods have provided access to the microsecond time regime, there is room for improvement in terms of temporal resolution and sensitivity. To address this need, we developed a continuous-flow mixing instrument with a dead time of 12 to 27 µs (depending on solution viscosity) and enhanced sensitivity, sufficient for monitoring tryptophan or tyrosine fluorescence changes at fluorophore concentrations as low as 1 µM. Relying on commercially available laser microfabrication services, we obtained an integrated mixer/flow-cell assembly on a quartz chip, based on a cross-channel configuration with channel dimensions and geometry designed to minimize backpressure. By gradually increasing the width of the observation channel downstream from the mixing region, we are able to monitor a reaction progress time window ranging from ~10 µs out to ~3 ms. By combining a solid-state UV laser with a Galvano-mirror scanning strategy, we achieved highly efficient and uniform fluorescence excitation along the flow channel. Examples of applications, including refolding of acid-denatured cytochrome c triggered by a pH jump and binding of a peptide ligand to a PDZ domain, demonstrate the capability of the technique to resolve fluorescence changes down to the 10 µs time regime on modest amounts of reagents.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9182321PMC
http://dx.doi.org/10.3390/molecules27113392DOI Listing

Publication Analysis

Top Keywords

advances mixer
8
mixer design
8
design detection
8
detection methods
8
microsecond time
8
time regime
8
fluorescence changes
8
time
5
methods kinetics
4
kinetics studies
4

Similar Publications

Recyclable Millable PolyureThane based on Enaminone Bonds With Upcycled Mechanical Performance.

Macromol Rapid Commun

January 2025

State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, 100029, China.

Thermoplastic polyurethane (TPU) exhibits re-processable properties, but the properties of TPU is deteriorated during the reprocessing for the oxidation and degradation of polymer chains. Meanwhile, although thermoset polyurethane exhibits excellent mechanical properties, it cannot be recycled for permanent crosslinking. Hence, it's still a challenge to obtain PU which exhibits the balance between the recyclability and mechanical properties.

View Article and Find Full Text PDF

Large-scale brainstem neuroimaging and genetic analyses provide new insights into the neuronal mechanisms of hypertension.

HGG Adv

January 2025

Norwegian Centre for Mental Disorders Research (NORMENT), Division of Mental Health and Addiction, Oslo University Hospital and University of Oslo, 0424 Oslo, Norway; Section for Precision Psychiatry, Division of Mental Health and Addiction, Oslo University Hospital, 0424 Oslo, Norway; Center for Precision Psychiatry, Division of Mental Health and Addiction, Institute of Clinical Medicine, University of Oslo, 0424 Oslo, Norway.

While brainstem regions are central regulators of blood pressure, the neuronal mechanisms underlying their role in hypertension remain poorly understood. Here, we investigated the structural and genetic relationships between global and regional brainstem volumes and blood pressure. We used magnetic resonance imaging data from n = 32,666 UK Biobank participants, and assessed the association of volumes of the whole brainstem and its main regions with blood pressure.

View Article and Find Full Text PDF

We experimentally demonstrate a dual-polarized, single-input single-output (SISO) photonic-electronic integrated system, achieving a single-wavelength data rate of 400 Gbit/s at 220 GHz. This system is based on a self-developed IQ mixer, orthomode transducers (OMTs), and a dual-polarized multiplexing antenna (DPMA). The IQ mixer front-end exhibits a conversion loss of over 14 dB within a 30 GHz bandwidth, and cross talk between IQ channels is better than 15 dB for most frequency points.

View Article and Find Full Text PDF

Consistent Evaluation Methods for Microfluidic Mixers.

Micromachines (Basel)

October 2024

Institute for Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Am Hofbräuhaus 1B, 96450 Coburg, Germany.

The study presents a unifying methodology for characterizing micromixers, integrating both experimental and simulation techniques. Focusing on Dean mixer designs, it employs an optical evaluation for experiments and a modified Sobolev norm for simulations, yielding a unified dimensionless characteristic parameter for the whole mixer at a given Reynolds number. The results demonstrate consistent mixing performance trends across both methods for various operation points.

View Article and Find Full Text PDF

Deep learning has made significant strides, driving advances in areas like computer vision, natural language processing, and autonomous systems. In this paper, we further investigate the implications of the role of additive shortcut connections, focusing on models such as ResNet, Vision Transformers (ViTs), and MLP-Mixers, given that they are essential in enabling efficient information flow and mitigating optimization challenges such as vanishing gradients. In particular, capitalizing on our recent information bottleneck approach, we analyze how additive shortcuts influence the fitting and compression phases of training, crucial for generalization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!