Circular hollow steel tube columns are widely used in high-rise buildings and bridges due to their ductility and lower weight compared to reinforced concrete. The use of this type of steel section has several advantages over using reinforced concrete members. The present study investigates the bending behavior of steel circular hollow sections when subjected to bending loads. The variations in material characteristics with regard to position along the cross-section of a steel tube member is first considered in this experimental study, providing for a more accurate definition of the material behavior in the model. A supported beam tested by two-point loads is the loading type that is used to study the bending performance of steel tubes. Ten circular hollow beam specimens were prepared and tested up to and post the failure stage with the following dimensions: thickness (2, 3, and 6 mm), diameter (76.2, 101.6, and 219 mm), and span (1000, 1500, and 2000 mm). A finite element analysis has been conducted for these ten specimens using the ANSYS program. The finite element model is compared to experimentally obtained data to verify that both local and global behaviors are correctly considered. The load-deflection results of this analysis showed a good agreement with the experimental results. A parametric study also was performed that considered two variables, which were the effect of the presence of circular rings and the change of opening location in the length direction on the specimens' behavior. This study showed that the presence of the circular rings in the specimen led to an increase in its ultimate strength (of 53.24%) compared with the non-presence of these rings. In contrast, the presence of openings at 30, 40, and 50% from the specimen length reduced the strength capacity by 8.76, 14.23, and 17.88%, respectively.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9182093 | PMC |
http://dx.doi.org/10.3390/ma15113919 | DOI Listing |
Biomed Phys Eng Express
January 2025
Electronics and Communication Engineering, SRM Institute of Science and Technology (Deemed to be University), Tech Park, SRM Nagar, Kattankulathur, Kattankulathur, Tamilnadu, 603203, INDIA.
This article proposes a novel biosensor based on a five-semi-circular cladding tube hollow core antiresonant fiber (HC-ARF) with a frequency range of 0.5-2.8 THz, using Zeonex as the background material.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Electrical Engineering, Iran University of Science and Technology, Tehran, 16846-1314, Iran.
The holographic technique is one of the simplest methods for designing antennas based on metasurface. This paper presents a spoof surface plasmon polariton (SSPP) leaky-wave antenna (LWA) based on the concept of impedance modulated metasurfaces by the anisotropic holographic technique. Instead of parasitic elements, anisotropic SSPP elements are exploited to achieve radiation with circular polarization.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Key Laboratory of Specialty Fiber Optics and Optical Access Networks, Shanghai University, Shanghai 200444, China.
A highly sensitive sensor, which can detect the temperature and strain simultaneously, is proposed using a hollow-core anti-resonant fiber with composite nested tubes. The sensing fiber contains two kinds of nested tubes, and two different sensing mechanisms, the resonance coupling effect and the intermodal interference, are realized in the same section of a hollow-core anti-resonant fiber fully filled with ethanol. Five conjoined nested anti-resonant tubes are introduced to suppress the confinement loss of the higher-order mode LP.
View Article and Find Full Text PDFACS Biomater Sci Eng
December 2024
Electrical and Computer Engineering, University of Virginia, Charlottesville, Virginia 22904, United States.
Cardiovascular diseases remain the leading cause of mortality, necessitating advancements in cardiac tissue engineering platforms for improved disease modeling, drug screening, and regenerative therapies. The chief challenge to recapitulating the beating behavior of cardiomyocytes is creation of the circular stress profile experienced by hollow organs in the natural heart due to filling pressure and integrated strategies for intercellular communication to promote cell-to-cell connections. We present a platform featuring addressable arrays of nanogrooved polydimethylsiloxane (PDMS) diaphragms for cell alignment and circular mechanical stimulation, with embedded silver nanowires (AgNWs) for electrical cues, so that cardiomyocyte functionality can be assessed under these synergistic influences.
View Article and Find Full Text PDFEnviron Sci Technol Lett
December 2024
George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 770 Ferst Drive NW, Atlanta, Georgia 30332, United States.
Recovery of nitrogen from wastewater presents a unique opportunity to valorize waste and contribute to a more circular nitrogen economy. However, dilute solution separations are challenging for most state-of-the-art separations technologies. This often results in technologies having low concentration factors that result in low-value products (e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!