Mercury sphygmomanometer based on traditional auscultation method is widely used in primary medical institutions in China, but a large amount of blood pressure data can not be directly recorded and applied in scientific research analysis, meanwhile auscultation data is the clinical standard to verify the accuracy of non-invasive electronic sphygmomanometer. Focusing on this, we designed a miniature non-invasive blood pressure measurement and verification system, which can assist doctors to record blood pressure data automatically during the process of auscultation. Through the data playback function,the software of this system can evaluate and verify the blood pressure algorithm of oscillographic method, and then continuously modify the algorithm to improve the measurement accuracy. This study introduces the hardware selection and software design process in detail. The test results show that the system meets the requirements of relevant standards and has a good application prospect.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3969/j.issn.1671-7104.2022.03.009 | DOI Listing |
BMC Nutr
January 2025
Department of Community Nutrition, School of Nutrition and Food Sciences, Shiraz University of Medical Sciences, Razi Blvd, Shiraz, 7153675541, Iran.
Background: The link between obesity and cardiometabolic risk has been well recognized. We investigated the association between body fat percentage (BF%), as an appropriate indicator of obesity, and prevalence of cardiometabolic diseases using baseline data of Fasa PERSIAN cohort study.
Methods: The cross-sectional study was performed on data obtained at the first phase of the Fasa cohort study in Iran (n = 4658: M/F: 2154/2504).
BMC Pediatr
January 2025
Faculty of Nursing, Yasouj University of Medical Sciences, Kohkiloyeh and Boyer-Ahmad, Yasuj, Iran.
Background: Early and continuous exposure to painful stimuli in premature infants leads to short-and long-term complications. Listening to white noise is an accessible and inexpensive non-invasive method that can be used as a safe nursing intervention in hospitals. This study aimed to assess white noise's effect on premature Infants' physiological parameters during peripheral intravenous catheter insertion.
View Article and Find Full Text PDFBMC Public Health
January 2025
UMR 1295, Paul Sabatier III University-Inserm, CERPOP: Centre for Epidemiology Research in Population Health, Toulouse, France.
Background: The cardiovascular consequences of night work are increasingly well-known. Implementing effective preventive strategies, however, requires further investigation of the effects of exposure duration. This study sought to assess the cumulative dose-effect of night work exposure on the prevalence of cardiovascular risk factors among current and former night workers in France.
View Article and Find Full Text PDFAnn Intensive Care
January 2025
Institute of Anesthesia and Intensive Care, Padova University Hospital, Padua, Italy.
Background: Prone position has been diffusely applied in mechanically ventilated COVID-19 patients. Our aim is ascertaining the association between the physiologic response and the length of the first cycle of prone position and intensive care unit (ICU) mortality.
Methods: International registry including COVID-19 adult patients who underwent prone positioning.
Int J Obes (Lond)
January 2025
Department of Biosciences, COMSATS University Islamabad, Park Road Tarlai, Islamabad, 45550, Pakistan.
Background: Obesity plays a crucial role in the development of metabolic disorders including diabetes, coronary and renal diseases. There are several factors involved in the pathology of obesity, including chronic inflammation and exposure to environmental contaminants. Recently, the cholinergic co-hydrolyzing enzyme BChE has been associated with clinical conditions such as diabetes and obesity.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!