Background: The assessment of biosafety of pharmacologically active substances is crucial for determining the feasibility of their medical use. There are controversial issues regarding the use of substances of different origins as implants.

Methods: We have conducted the comprehensive studies to determine the in vivo toxicity and in vitro genotoxicity of new generation of hydrophilic gel for implantation (production name of the substance "Activegel") to detail its characteristics and assess its biosafety.

Results: In vivo studies have shown the absence of clinical manifestations of intoxication in animals and no abnormalities in their physiological condition, general and biochemical blood tests. Evaluation of the site of the gel application showed no inflammatory reaction and evidenced on normal state of tissues of animal skin. The results of the genotoxicity test indicated that the gel did not affect the parameters of DNA comets and the formation of micronuclei, accordingly, had no genotoxic effect on human peripheral blood lymphocytes. When studying the effect of the gel on malignantly transformed cells in vitro, it was found that the gel for implantation did not change the proliferative activity and viability of human breast cancer cells.

Conclusions: Comprehensive in vitro and in vivo study using various experimental model systems showed that the hydrophilic gel for implantation "Activegel" is non-toxic.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9178808PMC
http://dx.doi.org/10.1186/s40360-022-00577-3DOI Listing

Publication Analysis

Top Keywords

gel implantation
16
hydrophilic gel
12
assessment biosafety
8
vitro vivo
8
gel
7
biosafety toxicity
4
toxicity hydrophilic
4
implantation
4
implantation experimental
4
vitro
4

Similar Publications

Background: Regenerative endodontics requires an innovative delivery system to release antibiotics/growth factors in a sequential trend. This study focuses on developing/characterizing a thermoresponsive core-shell hydrogel designed for targeted drug delivery in endodontics.

Methods: The core-shell chitosan-alginate microparticles were prepared by electrospraying to deliver bone morphogenic protein-2 for 14 days and transforming growth factor-beta 1 (TGF-β1) for 7-14 days.

View Article and Find Full Text PDF

Bacterial infections are a common cause of clinical complications associated with the use of orthodontic microimplants. Biofilm formation on their surfaces and subsequent infection of peri-implant tissues can result in either exfoliation or surgical removal of these medical devices. In order to improve the properties of microimplants, hybrid coatings enriched with silver nanoparticles, calcium, and phosphorus were investigated.

View Article and Find Full Text PDF

Bone tissue engineering is a technique that simulates the bone tissue microenvironment by utilizing cells, tissue scaffolds, and growth factors. The collagen hydrogel is a three-dimensional network bionic material that has properties and structures comparable to those of the extracellular matrix (ECM), making it an ideal scaffold and drug delivery system for tissue engineering. The clinical applications of this material are restricted due to its low mechanical strength.

View Article and Find Full Text PDF

Evidence has shown the clear positive effects of nature-based products on biofilm control and improved gingival health. However, most studies have used in vitro models, have tested single natural components, or have not evaluated proteomic changes after treatment. This double-blind, parallel, randomized, and controlled clinical trial evaluated the benefits of a nature-based gel in controlling gingival inflammation and its effects on the proteomic gingival crevicular fluid (GCF) profile.

View Article and Find Full Text PDF

Background: T thermometry is considered a straight method for the safety monitoring of patients with deep brain stimulation (DBS) electrodes against radiofrequency-induced heating during Magnetic Resonance Imaging (MRI), requiring different sequences and methods.

Objective: This study aimed to compare two T thermometry methods and two low specific absorption rate (SAR) imaging sequences in terms of the output image quality.

Material And Methods: In this experimental study, a gel phantom was prepared, resembling the brain tissue properties with a copper wire inside.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!