A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluating Nanoparticle Hydrophobicity Using Analytical Membrane Hydrophobic Interaction Chromatography. | LitMetric

Evaluating Nanoparticle Hydrophobicity Using Analytical Membrane Hydrophobic Interaction Chromatography.

Anal Chem

Department of Chemical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States.

Published: June 2022

Nanoparticle hydrophobicity is a key factor controlling the stability, adhesion, and transport of nanoparticle suspensions. Although a number of approaches have been presented for evaluating nanoparticle hydrophobicity, these methods are difficult to apply to larger nanoparticles and viruses (>100 nm in size) that are of increasing importance in drug delivery and gene therapy. This study investigated the use of a new analytical hydrophobic interaction chromatography method employing a 5.0 μm pore size polyvinylidene fluoride membrane as the stationary-phase in membrane hydrophobic interaction chromatography (MHIC). Experimental data obtained using a series of model proteins were in good agreement with literature values for the hydrophobicity (both experimental and computational). MHIC was then used to evaluate the hydrophobicity of a variety of nanoparticles, including a live attenuated viral vaccine, both in water and in the presence of different surfactants. This new method can be implemented on any liquid chromatography system, run times are typically <20 min, and the experiments avoid the use of organic solvents that could alter the structure of many biological nanoparticles.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.2c00710DOI Listing

Publication Analysis

Top Keywords

nanoparticle hydrophobicity
12
hydrophobic interaction
12
interaction chromatography
12
evaluating nanoparticle
8
membrane hydrophobic
8
hydrophobicity
5
hydrophobicity analytical
4
analytical membrane
4
chromatography
4
chromatography nanoparticle
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!