Biull Eksp Biol Med
Published: April 1987
The heart rate and intraatrial latencies between epicardial electrograms from three sites of the right atrium have been studied during vagal stimulation in open-chest dogs. It has been shown that alterations of latencies started at a certain cardiac cycle length irrespective of pacing frequency. A transitional process of changes from a steady latency value in the control to another steady value during vagal stimulation has been observed. The transitional process has been simulated in experimental procedure in which two sites of the right atrium were paced at close and constant frequencies. To interpret the results obtained one-dimensional model of the sinus node has been constructed. According to the model, pacemaker shift within the sinus node results from a competition between two foci of automaticity with close intrinsic frequencies.
Download full-text PDF |
Source |
---|
BMC Cardiovasc Disord
March 2025
Department of Cardiology, The Second Affiliated Hospital, Yuying Children's Hospital of Wenzhou Medical University, No.109 Xueyuan West Road, Lucheng District, Wenzhou, Zhejiang, 325000, PR China.
Aims: To investigate the characteristics of bipolar intracardiac electrograms (bi-EGMs) in target sites of ventricular arrhythmias (VAs) originating from the distal great vein system (DGCVs).
Methods: 169 patients undergoing first-time ablation for VAs originated from DGCVs were enrolled in present study. Successful ablation was achieved in 146 patients.
Surg Case Rep
February 2025
Department of Gastroenterological Surgery and Pediatric Surgery, Gifu University Graduate School of Medicine, Gifu, Gifu, Japan.
Introduction: The right top pulmonary vein (RTPV) is a rare anatomical variant that arises independently of the right superior lobe. It drains behind the right main bronchus or bronchus intermedius and into the left atrium or another pulmonary vein. This anomaly poses challenges during subcarinal lymph node dissection in thoracic surgery, such as esophagectomy, owing to the risk of vascular injury.
View Article and Find Full Text PDFCell Commun Signal
March 2025
Institute of Cardiovascular Diseases, Department of Cardiovascular Surgery, TEDA International Cardiovascular Hospital, Tianjin University & Chinese Academy of Medical Sciences & Peking Union Medical College, No.61, 3rd Ave, TEDA, Tianjin, 300457, China.
Background: Atrial fibrillation (AF) is the most common form of arrhythmia and is a growing clinical problem. Post-translational modifications (PTMs) constitute crucial epigenetic mechanisms but modification of lysine 2-hydroxyisobutyrylation (K) in AF is still unknown. This study aimed to investigate the role and mechanism of K in AF.
View Article and Find Full Text PDFEuropace
February 2025
Arrhythmia Department, Teknon Heart Institute, Teknon Medical Center, C/Vilana 12, Barcelona 08022, Spain.
Aims: Electrical reconnections between pulmonary veins (PVs) and the left atrium (LA) are frequently responsible for atrial fibrillation (AF) recurrences after pulmonary vein isolation (PVI). Multidetector computed tomography (MDCT)-derived images can be post-processed to detect intramyocardial fat (inFAT) by signal radiodensity thresholding. The role of inFAT on PV-LA reconnections remains unknown.
View Article and Find Full Text PDFMed Image Anal
April 2025
Computational Multiscale Simulation Lab (CoMMLab), Department of Computer Science and Department of Electronic Engineering, Universitat de València, Av. de l'Universitat s/n, Burjassot 46100, Spain. Electronic address:
In silico models offer a promising advancement for studying cardiac arrhythmias and their clinical implications. However, existing detailed mathematical models often suffer from prolonged computational time compared to diagnostic needs. This study introduces a Cellular Automaton (CA) model tailored to replicate atrial electrophysiology in different stages of Atrial Fibrillation (AF), including persistent AF (PsAF).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!
© LitMetric 2025. All rights reserved.