Purpose: To evaluate the visual performance and clinical outcomes after implantation of Lucidis EDOF IOL following cataract surgery.
Design: In this retrospective study, medical records from all enrolled patients were analyzed, and the following information was extracted retrospectively over 3 months following surgery.
Materials And Methods: We reviewed retrospectively 181 eyes of 98 patients, who underwent cataract surgery with Lucidis extended depth of focus IOL.
Results: 44 patients were males (45%) and 54 were females (55%). The average age of the study population was 68 ± 11 years. The mean preoperative BCVA (logMAR) was 0.19 ± 0.18. The mean root mean square (RMS) high order aberration (HOA) was 0.18 ± 0.1. Monocular BCVA results were 0.02 ± 0.04 (logMAR) and 0.028 ± 0.04 (logMAR) 1 month and 3 months postoperatively, respectively. Between the baseline and 1-month measures, monocular distance BCVA improved by an average of 0.17 ± 0.14 logMAR ( = 0.0001). Between the baseline and 3-month postoperative measures, monocular distance BCVA improved by an average of 0.16 ± 0.13 logMAR ( = 0.0001). Monocular UDVA 1 and 3 months postoperatively was 0.08 ± 0.1 logMAR and 0.067 ± 0.08 logMAR, respectively. 1-Month postoperative binocular UDVA was 0.036 ± 0.05 logMAR, binocular UIVA was 0.1 ± 0.08 logMAR, and binocular UNVA was 0.12 ± 0.14 logMAR. 3-Month postoperative binocular UDVA was 0.038 ± 0.05 logMAR, binocular UIVA was 0.09 ± 0.1 logMAR, and binocular UNVA was 0.16 ± 0.14 logMAR.
Conclusions: Lucidis EDOF IOL achieves good visual performances in all distances.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9167139 | PMC |
http://dx.doi.org/10.1155/2022/5100861 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!