Simultaneous determination of hydrochlorothiazide, amlodipine, and telmisartan with spectrophotometric and HPLC green chemistry applications.

Chemosphere

Department of Chemistry, Soongsil University, Seoul, 06978, South Korea; Department of Sustainable Engineering, Saveetha School of Engineering, SIMATS, Chennai, 602105, India; Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran. Electronic address:

Published: September 2022

For the quantifiable amounts of Telmisartan (TLM) and Hydrochlorothiazide (HYD) in the presence of Amlodipine (AML) in a ternary mixture of synthetic laboratory mixture, a novel, sensitive, quick, and practical reversed-phase high-performance liquid chromatography (RP-HPLC) method was given. In order to separate, a Waters Spherisorb ODS-2 C18 column was used. For HYD, TLM, and AML, these techniques were viable over linearity ranges of 4-12 μg/mL, 4-25 μg/mL, and 5-40 μg/mL, respectively. The mobile phase system was acetonitrile:methanol: phosphate buffer at pH 2.5 (65:5:30 v/v/v), and the flow rate was 1.5 mL/min. Novel spectrophotometric methods were applied for active substances to determine simultaneously. The first method is absorptivity centering using factorized spectrum, and the second method is dual amplitude difference coupled with absorbance subtraction. These approaches have been effectively applied to bulk, laboratory synthetic mixtures to employ active components quantitatively. Correlation coefficients were found to be higher than 0.99 and the limit of detection values lower than 0.49 μg/mL in both spectrophotometric methods. The methodologies were validated following ICH recommendations. In the developed HPLC method, the limit of detection values was found to be 0.01 μg/mL for HYD and 0.02 μg/mL for AML and TLM. The correlation coefficients for the HPLC method were found to be 0.9971 for HYD, 0.9990 for AML, and 0.9983 for TLM. The suggested HPLC technique is a simple, effective, sensitive, environmentally friendly, and time-saving approach for determining TLM and HYD in the presence of AML.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chemosphere.2022.135074DOI Listing

Publication Analysis

Top Keywords

hyd presence
8
spectrophotometric methods
8
correlation coefficients
8
limit detection
8
detection values
8
hplc method
8
tlm
5
hyd
5
aml
5
method
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!