In charged-particle therapy, a ripple filter (RiFi) is used for broadening the Bragg peak in the beam direction. A conventional RiFi consists of plates with a fine ridge and groove structure. The construction of the RiFi has been a time-consuming and costly task. In this study, we developed a simple RiFi made of multi-layered metal mesh (mRiFi), with which the Bragg peak is broadened due to structural randomness, similar to what occurs for the already proposed RiFi with porous material.. The mRiFi was constructed by stacking commercially available metal meshes at random positions and angles. The mRiFi was inexpensive to fabricate due to its high availability and low machining accuracy. The Bragg peak width modulated by the mRiFi can be uniquely determined by the wire material, wire diameter, wire-to-wire spacing of the metal mesh, and the number of mesh sheets. We fabricated four mRiFis consisting of 10, 20, 30, and 40 layers of stainless steel meshes with a wire diameter of 0.1 mm and a wire-to-wire spacing of 0.508 mm.Using the mRiFis consisting of 10, 20, 30, and 40 mesh sheets, we succeeded in broadening the Bragg peak following the normal distribution with the respective standard deviationvalues of 0.83, 1.15, 1.41, and 1.56 mm in water in experimental planar-integrated depth dose measurements with 140.3 MeV ucarbon-ion beams. The effect of range broadening with the mRiFi was independent of its lateral position, and the measurement of the surface dose using radiochromic films showed no severe inhomogeneity with a homogeneity index greater than 0.3 caused by the mRiFis.The developed mRiFi can be used as a RiFi in charged-particle therapy. The mRiFi has three advantages: high supply stability of the material for manufacturing it, easy fabrication, and low cost.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/ac762d | DOI Listing |
Clin Transl Radiat Oncol
March 2025
Department of Molecular Genetics, Oncode Institute, Erasmus MC Cancer Institute, Erasmus University Medical Center, Rotterdam, Netherlands (the).
Background And Purpose: Radiotherapy induces tumor cell killing by generating DNA double strand breaks (DSBs). The effectiveness of radiotherapy is significantly influenced by the repair of DSBs, which counteracts this lethal effect. Current investigations are focused on determining whether non-homologous end joining (NHEJ) or homologous recombination is the predominant repair pathway following proton and photon radiation.
View Article and Find Full Text PDFA wavelength demodulation method for ultra-short fiber Bragg grating (US-FBG) sensors based on an arrayed waveguide grating (AWG) and a convex optimization algorithm is proposed and demonstrated. Instead of measuring the output power ratio of the two adjacent AWG channels as previously done, in this work the wavelength demodulation is realized by reconstructing the US-FBG spectrum. The principle of spectral reconstruction involves using an AWG to sample the spectral information of US-FBG and constructing underdetermined matrix equations with the obtained prior information on transmission responses and the detected output power from multiple AWG channels.
View Article and Find Full Text PDFMed Phys
December 2024
Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Background: A passive dosimeter framework for the measurement of dose in carbon ion beams has yet to be characterized or implemented for regular use.
Purpose: This work determined the dose calculation correction factors for absorbed dose in thermoluminescent dosimeters (TLDs) in a therapeutic carbon ion beam. TLD could be a useful tool for remote audits, particularly in the context of clinical trials as new protocols are developed for carbon ion radiotherapy.
Sensors (Basel)
November 2024
Optics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK.
A respiration rate (RR) monitoring system was created by integrating a Fibre Bragg Grating (FBG) optical fibre sensor into a respirator mask. The system exploits the sensitivity of an FBG to temperature to identify an individual's RR by measuring airflow temperature variation near the nostrils and mouth. To monitor the FBG response, a portable, battery-powered, wireless miniature interrogator system was developed to replace a relatively bulky benchtop interrogator used in previous studies.
View Article and Find Full Text PDFRadiother Oncol
December 2024
Department of Experimental Clinical Oncology, Aarhus University Hospital, Denmark; Danish Center for Particle Therapy, Aarhus University Hospital, Denmark; Department of Clinical Medicine, Aarhus University Hospital, Denmark.
Background And Purpose: In proton therapy, a relative biological effectiveness (RBE) of 1.1 is used toreach an isoeffective biological response between photon and proton doses. However, the RBE varies with biological endpoints and linear energy transfer (LET), two key parameters in radiotherapy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!