A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Red Blood Cell Membrane-Coated Ultrasmall NaGdF Nanoprobes for High-Resolution 3D Magnetic Resonance Angiography. | LitMetric

Enhanced angiography based on magnetic resonance imaging (MRI) has emerged as a noninvasive, robust, and high-resolution imaging technique for the clinical evaluation of vascular diseases. However, the effects of clinical Gd-chelating contrast agents are unsatisfactory for MRI contrast enhancement owing to their short blood half-life caused by rapid vascular extravasation, especially in microvessels. To address these issues, nanoprobes based on red blood cell membrane-coated ultrasmall NaGdF nanoparticles that exhibit much higher longitudinal molar relaxivity () than the clinically used contrast agent gadolinium diethylenetriaminepentaacetic acid have been developed. Furthermore, the appropriate hydrodynamic diameter and stealth nature aid the nanoprobes to reside longer within the blood vessels without extravasation, thereby increasing the contrast between the blood vessels and surrounding tissues. Through probe-enhanced three-dimensional (3D) dynamic contrast-enhanced MR angiography, the main arteries and veins of the mouse were readily discernible, and even tiny vessels with sub-millimeter diameters could be clearly depicted. With this level of outstanding MR angiography performance, the embolization and recanalization processes of the carotid artery can be serially monitored with high imaging resolution using only a single injection. Additionally, the results of clearance studies and the toxicity tests further highlight the safety features of the nanoprobe. To summarize, the nanoprobes used in this study exhibit less extravascular leakage and a longer blood half-life, thus successfully overcoming the defects of the conventional low-molecular-weight Gd-based contrast agents and demonstrating their potential usefulness in enhanced MR angiography.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.2c03530DOI Listing

Publication Analysis

Top Keywords

red blood
8
blood cell
8
cell membrane-coated
8
membrane-coated ultrasmall
8
ultrasmall nagdf
8
magnetic resonance
8
enhanced angiography
8
contrast agents
8
blood half-life
8
longer blood
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!