Background: Paravalvular leak (PVL), also known as paravalvular prosthetic regurgitation, is not a rare complication after surgical valve replacement, and it may cause varying degrees of heart failure. The transcatheter closure of PVL is technically demanding and challenging.

Case Summary: A 68-year-old man presented with degenerative mitral regurgitation with heart failure, New York Heart Association functional class 3. He received bioprosthetic mitral valve replacement in December 2019. PVL was noted at the location of the aorto-mitral curtain in transesophageal echocardiography without signs of endocarditis or dehiscence of the bioprosthetic valve. Transseptal transcatheter closure of the mitral PVL was performed efficiently using the EchoNavigator virtual marker and Agilis NxT steerable introducer.

Conclusion: This case highlights that the EchoNavigator virtual marker and Agilis NxT steerable introducer can facilitate transseptal transcatheter closure of mitral PVL by reducing the procedure time and contrast media.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9131240PMC
http://dx.doi.org/10.12998/wjcc.v10.i13.4236DOI Listing

Publication Analysis

Top Keywords

transcatheter closure
16
echonavigator virtual
12
virtual marker
12
marker agilis
12
agilis nxt
12
nxt steerable
12
transseptal transcatheter
12
closure mitral
12
steerable introducer
8
introducer facilitate
8

Similar Publications

Patent Ductus Arteriosus Morphology Changes in Preterm Neonates Undergoing Transcatheter Device Closure.

Pediatr Cardiol

January 2025

Division of Cardiology, Children's Healthcare of Atlanta, Emory University School of Medicine, 2970 Brandywine Rd, Suite 125, Atlanta, GA, 30341, USA.

Evaluate patent ductus arteriosus (PDA) morphology changes in the preterm neonate undergoing transcatheter PDA closure (TCPC). We propose the type F ductus is associated with lower corrected gestational age (CGA) and improved TCPC outcomes. Retrospective review of premature neonates undergoing TCPC at a large volume institution from November 2020 to November 2023.

View Article and Find Full Text PDF

Background: Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.

Methods: From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation.

View Article and Find Full Text PDF

Background: Since patients with congenital heart defects (CHD) frequently require life-long medical care and repeat invasive treatment, radiation exposure during interventional procedures is a relevant issue concerning potential radiation related risks. Therefore, an analysis on radiation data from the German Registry for Cardiac Operations and Interventions in patients with CHD was performed.

Methods: From January 2012 until December 2020 a total of 28,374 cardiac catheter interventions were recorded.

View Article and Find Full Text PDF

Background: Historically, percutaneous transcatheter left atrial appendage closure (LAAC) has been performed under general anesthesia (GA) with transesophageal echocardiographic images obtained by a noninvasive cardiologist and usually requires an overnight hospital stay. Alternatively, we present our single-center experience performing LAACs under deep sedation (DS), employing an echocardiographic technician instead of a noninvasive cardiologist, and expediting same-day discharge. Mid- to long-term outcomes were also evaluated with follow-up imaging at a 45-day visit.

View Article and Find Full Text PDF