The main purpose of a radiologist's expertise in evaluation of anal fistula magnetic resonance imaging (MRI) is to benefit patients by decreasing the incontinence rate and increasing the healing rate. Any loss of vital information during the transfer of this data from the radiologist to the operating surgeon is unwarranted and is best prevented. In this regard, two methods are suggested. First, a short video to be attached with the standardized written report highlighting the vital parameters of the fistula. This would ensure minimum loss of information when it is conveyed from the radiologist to the operating surgeon. Second, inclusion of a new parameter, the amount of external sphincter involvement by the anal fistula. This parameter is usually not included in the MRI report. This can be evaluated as the height of penetration of the external anal sphincter (HOPE) by the fistula. The external anal sphincter plays a pivotal role in maintaining continence. This parameter (HOPE) is distinct from the 'height of internal opening' and assumes immense importance as its knowledge is paramount to prevent damage to the external anal sphincter by the surgeon during surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9131832PMC
http://dx.doi.org/10.4240/wjgs.v14.i4.271DOI Listing

Publication Analysis

Top Keywords

external anal
16
anal fistula
12
anal sphincter
12
penetration external
8
magnetic resonance
8
resonance imaging
8
radiologist operating
8
operating surgeon
8
anal
7
external
5

Similar Publications

Nanofluidic iontronics, including the field-effect ionic diode (FE-ID) and field-effect ionic transistor (FE-IT), represent emerging nanofluidic logic devices that have been employed in sensitive analyses. Making analyte recognitions in predefined nanofluidic devices has been verified to improve the sensitivity and selectivity using a single ionic signal, such as ionic current amplification, rectification, and Coulomb blockade. However, the detection of analytes in complex systems generally necessitates more diverse signals beyond just ionic currents.

View Article and Find Full Text PDF

Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance.

Anal Chem

January 2025

Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.

Microelectrodes offer exceptional sensitivity, rapid response, and versatility, making them ideal for real-time detection and monitoring applications. Photoelectrochemical (PEC) sensors have shown great value in many fields due to their high sensitivity, fast response, and ease of operation. Nevertheless, conventional PEC sensing relies on cumbersome external light sources and bulky electrodes, hindering its miniaturization and implantation, thereby limiting its application in real-time disease monitoring.

View Article and Find Full Text PDF

Enhancing lesion detection in automated breast ultrasound using unsupervised multi-view contrastive learning with 3D DETR.

Med Image Anal

January 2025

National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China; Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, China; Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, China; School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China. Electronic address:

The inherent variability of lesions poses challenges in leveraging AI in 3D automated breast ultrasound (ABUS) for lesion detection. Traditional methods based on single scans have fallen short compared to comprehensive evaluations by experienced sonologists using multiple scans. To address this, our study introduces an innovative approach combining the multi-view co-attention mechanism (MCAM) with unsupervised contrastive learning.

View Article and Find Full Text PDF

Background: Compound schizonepeta fumigation lotion is a type of Chinese patent medicine for external use. It has the effect of dispelling wind, eliminating dampness, reducing swelling, and relieving pain. Clinically, it is used for anal fumigation and treatment of external hemorrhoids, anal fissures, and other diseases.

View Article and Find Full Text PDF

Reversed anatomy in transanal lateral lymph node dissection: landmarks and pitfalls.

Tech Coloproctol

January 2025

Department of Colorectal Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.

Lateral lymph node dissection (LLND) is getting global attention as an a surgical option to reduce local recurrence in locally advanced rectal cancer. As the transanal total mesorectal excision (TaTME) is gaining popularity worldwide, a novel LLND approach was established adopting a two-team approach that combines the transabdominal and transanal approaches using the TaTME technique. This narrative review describes the advantages, anatomical landmarks, surgical techniques, and pitfalls of transanal LLND (TaLLND).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!