Background: Anterior knee pain can arise from several sources. One of the main sources of pain in patients with anterior knee pain is the patella. Increased patellofemoral joint loading is the prime source of patellar pain. Elevated intraosseous pressures have been measured in painful patellae and increasing the intraosseous fluid pressure in the patella causes pain. Whether elevated fluid pressure is an independent source of pain or if the patellar deformation under load leads to elevated pressure and pain has not been determined. Our hypothesis was that the patella deforms measurably under physiologic loads and that intraosseous pressure increase is related to that deformation. The relationship may be linear as measured by correlation or nonlinear as measured by the sum of squared error.

Methods: Part I: Assessment of patellar load-deformation profiles were obtained in 2 intact cadaver patellae and 1 bisected patella under physiologic loads. Part II: Measurements of intraosseous pressure were obtained in 9 cadaver patellae as the patellae were compressed with physiologic loads. Pressures were recorded at sequential levels of anterior-posterior patellar compression.

Findings: Cadaver patellae compress up to 3.5 mm in the anterior-posterior plane. Compression with physiologic forces raises intraosseous pressure to more than 40 mmHg.

Interpretation: Load-deformation of cadaver patellae results in deformation and an increase in intraosseous pressure. These findings may help explain previous studies of patellofemoral pain where elevated patellar intraosseous pressures have been found in vivo.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2022.105681DOI Listing

Publication Analysis

Top Keywords

cadaver patellae
20
intraosseous pressure
20
pain elevated
12
physiologic loads
12
intraosseous
8
pressure
8
anterior knee
8
pain
8
knee pain
8
intraosseous pressures
8

Similar Publications

Purpose: To biomechanically compare primary medial patellofemoral ligament (MPFL) repair (MPFLr) augmented with a reinforced bioinductive implant (RBI) to the native MPFL ligament and a semitendinosus (semi-T) MPFL reconstruction (MPFLR) at time zero.

Methods: Four fresh-frozen matched pair cadavers (8 knees) were used to biomechanically compare the native MPFL to augmented MPFLr (n = 4) and semi-T MPFLR (n = 4). The native MPFL (n = 8) was isolated, preserving the femoral and patellar attachments, and pulled to failure.

View Article and Find Full Text PDF

Introduction: Adjunctive suture augmentation of patellar plate fixation has yet to be investigated. Our biomechanical study sought to evaluate whether suture augmentation improves dorsal patellar locking plate fixation. Our hypothesis was that suture augmentation would improve fixation of this construct.

View Article and Find Full Text PDF

Intramuscular neural distribution of the vastus medialis for botulinum neurotoxin injection: application to spasticity.

Surg Radiol Anat

December 2024

Department of Anatomy, School of Medicine, CHA University, 120, Haeryong-ro, Pocheon-si, Gyeonggi-do, 11160, Republic of Korea.

Purpose: A comprehensive understanding of neural distribution within the vastus medialis is crucial for the effective administration of botulinum neurotoxin injections to manage spasticity. The aim of this study was to develop an anatomically informed approach to guide the administration of botulinum neurotoxin injections into the vastus medialis muscle.

Methods: Using a modified Sihler's method, we examined the vastus medialis muscles (20 specimens) to delineate the distribution of nerves relative to a transverse line extending from the anterior superior iliac spine to the base of patella.

View Article and Find Full Text PDF

Purpose: This paper investigates the biomechanical benefits of using hybrid constructs that combine cannulated screws with tension band wiring (TBW) cerclage compared to cannulated screws with anterior Variable Angle locking neutralisation plates (VA LNP). These enhancements can bear heavier loads and maintain the repaired patella's integrity, in contrast to traditional methods.

Method: Eighteen fresh-frozen human cadaver patellae were carefully fractured transversely at their midpoints using a saw.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to assess whether kinematic alignment (KA) outperforms mechanical alignment (MA) in restoring patellar tracking to native patterns by using a clustering algorithm.

Methods: Twenty cadavers (40 knees) were evaluated. For each cadaver, one knee was randomly assigned to KA and the other to MA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!