Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Freehand single photon emission computed tomography (fhSPECT) is a technique that is used to monitor body's radioactivity intraoperatively. Accordingly, in this study, the feasibility of using fhSPECT for intraoperative 3D mapping in radioguided parathyroidectomy has been assessed. Patients, who were diagnosed with primary hyperparathyroidism consecutively, were scanned intraoperatively using fhSPECT to locate parathyroid adenomas before surgical procedure. The fhSPECT images were acquired intraoperatively using a declipseSPECT device (SurgicEye). The fhSPECT protocol could not be completed due to the technical problems in one patient. Parathyroid adenoma was located in the first patient with no lateral deviation. Nevertheless, a deviation of 8 mm was detected in the depth of the parathyroid adenoma, which is the distance of parathyroid adenoma from the skin. A 20 mm lateral deviation and a 10 mm deviation in depth were detected in the second patient. In the third patient, as was the case in the first patient, parathyroid adenoma was located with no lateral deviation. However, there was a 15 mm deviation in the depth of the parathyroid adenoma. A 5 mm lateral deviation was detected in the fourth patient yet with no deviation in the depth of parathyroid adenoma. Finally, neither lateral nor vertical deviation was detected in fifth patient. Based on the findings of this study, it was concluded that the fhSPECT technology can be helpful to a certain degree in locating the parathyroid adenoma. However, further studies are needed to support the findings of this preliminary study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s13304-022-01300-x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!