Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Granular activated carbon (GAC) was harvested from six filter-adsorbers that are used for taste and odour control in three drinking water treatment plants in Ontario, Canada, and evaluated for the removal of perfluorooctanic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) using minicolumn tests under different operational conditions. Parallel column tests were conducted using unsterilized GAC and sterilized GAC to distinguish adsorption from potential biodegradation of PFOA and PFOS across the GAC. It was observed that the GAC could achieve approximately 20% to 55% of PFOA and PFOS removal even after a long period of GAC operation (e.g., 6 years). There was no evidence of PFOA and PFOS biodegradation, so the removal in GAC can be attributed solely to adsorption under the conditions tested. However, in one location, there was evidence suggesting both removal and formation of PFOS and PFOA across the GAC, with the formation presumably due to the biotransformation of pre-existing precursors in the source water. Additionally, GAC service time and empty bed contact time (EBCT) were identified to be important factors that could affect the removal of PFOA and PFOS. Based on this information, an empirical model was proposed to predict PFOA and PFOS removal in GAC filter-adsorbers as a function of GAC service time and EBCT. This study provides useful information for utilities that have installed GAC for taste and odour control but may consider per- and polyfluoroalkyl substances (PFAS) removal as an additional voluntary objective or due to more stringent guidelines.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.scitotenv.2022.156406 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!