British Columbia (BC) implemented the syphilis reverse screening algorithm and Treponema pallidum PCR testing in 2014. We summarize the performance characteristics of the algorithm, together with PCR direct detection, and report on syphilis cases identified from 2015 to 2020. Prior to 2015, samples for syphilis diagnosis were first screened by rapid plasma reagin (RPR). As of 2015, sera were screened by the Siemens Advia Centaur syphilis assay (enzyme immunoassay [EIA]). Positive and equivocal samples were reflex tested by a T. pallidum passive particle agglutination assay (TPPA) and RPR. We used T. pallidum DNA PCR on clinical samples and restriction fragment length polymorphism analysis to identify azithromycin resistance mutations. Case/epidemiological data were obtained from the BC surveillance system. Of 1,631,519 samples screened by the EIA, 72,492 (4.4%) were positive and 187 (<0.1%) were equivocal. Of EIA-positive/equivocal samples, 10.6% were false positive, and false positivity was higher at lower EIA indices. The reverse algorithm detected 4,693 late latent syphilis cases that likely would have been missed by RPR screening. PCR had a very high sensitivity of 100% versus 52.9% and 52.4% for dark-field (DF) and immunofluorescence (IF) microscopy, respectively. The azithromycin resistance mutation A2058G was identified in 96% of PCR-positive samples, and A2059G was identified in 4%. Annually, there were 944 to 1,467 syphilis cases, with 62% in men who reported male sexual partners. The reverse algorithm had a low false-positive rate and very few equivocal screening results but did identify previously undiagnosed late latent syphilis cases. PCR was more sensitive than both DF and IF microscopy for direct diagnosis and enabled monitoring for azithromycin resistance. In this study, we summarize the performance characteristics of the algorithm, together with PCR direct detection and epidemiological analysis, and report on syphilis cases identified from 2015 to 2020. This allowed us to paint a complete picture of the outcome of the utilization of the reverse algorithm for diagnosing syphilis cases. The study clearly showed that the reverse algorithm had a low false-positive rate and very few equivocal screening results but did identify previously undiagnosed late latent syphilis cases. PCR was more sensitive than both DF and IF microscopy for direct diagnosis and enabled monitoring for azithromycin resistance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9241594PMC
http://dx.doi.org/10.1128/spectrum.00686-22DOI Listing

Publication Analysis

Top Keywords

treponema pallidum
8
algorithm pcr
8
2015 2020
8
british columbia's
4
columbia's experience
4
experience implementation
4
implementation treponema
4
pallidum
4
pallidum reverse
4
reverse algorithm
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!