Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Significance: This study obtained normative database for angle κ using Orbscan 3. The average angle κ values were 2.3 ± 1.34° in the whole sample, 2.23 ± 1.36° in myopic eyes, and 3.3 ±1.5° in hyperopic eyes. This is very important to optimize refractive surgery outcomes.
Purpose: The aim of this cross-sectional study was to obtain the value of mean angle κ in normal eyes of patients seeking laser vision correction, by the Orbscan 3.
Methods: The study was conducted on healthy eyes of people seeking laser refractive surgery. A total of 1815 eyes of 908 candidates were included. These were examined as a part of pre-operative assessment. Orbscan 3 was used to measure angle κ and its XY intercepts, keratometry readings, central corneal thickness, thinnest location, white-to-white diameter, and corneal asphericity of front surface (Qf) and back surface (Qb).
Results: The mean ± standard deviation angle κ in all eyes was 2.3 ± 1.34°. The values were 2.23 ± 1.36° in myopic eyes, 3.3 ±1.5° in hyperopic eyes, and 2.9 ±1.6° in emmetropic eyes. Positive correlation was found between angle κ and age, spherical equivalent, subjective sphere, and white-to-white diameter. On the other hand, axial length, average keratometry, central corneal thickness, pupil diameter, and asphericity Q front were negatively correlated with angle κ.
Conclusions: The mean ± standard deviation angle κ value measured by the Orbscan 3 was 2.3 ± 1.34°. This could be attributed to different software used, in addition to the relatively high axial length in the studied eyes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/OPX.0000000000001910 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!