Objective: To investigate the effect of the in situ screw implantation region and angle on the stability of lateral lumbar interbody fusion (LLIF) from a biomechanical perspective.
Methods: A validated L2-4 finite element (FE) model was modified for simulation. The L3-4 fused segment undergoing LLIF surgery was modeled. The area between the superior and inferior edges and the anterior and posterior edges of the vertebral body (VB) is divided into four zones by three parallel lines in coronal and horizontal planes. In situ screw implantation methods with different angles based on the three parallel lines in coronal plane were applied in Models A, B, and C (A: parallel to inferior line; B: from inferior line to midline; C: from inferior line to superior line). In addition, four implantation methods with different regions based on the three parallel lines in horizontal plane were simulated as types 1-2, 1-3, 2-2, and 2-3 (1-2: from anterior line to midline; 1-3: from anterior line to posterior line; 2-2: parallel to midline; 2-3: from midline to posterior line). L3-4 ROM, interbody cage stress, screw-bone interface stress, and L4 superior endplate stress were tracked and calculated for comparisons among these models.
Results: The L3-4 ROM of Models A, B, and C decreased with the extent ranging from 47.9% (flexion-extension) to 62.4% (lateral bending) with no significant differences under any loading condition. Types 2-2 and 2-3 had 45% restriction, while types 1-2 and 1-3 had 51% restriction in ROM under flexion-extension conditions. Under lateral bending, types 2-2 and 2-3 had 70.6% restriction, while types 1-2 and 1-3 had 61.2% restriction in ROM. Under axial rotation, types 2-2 and 2-3 had 65.2% restriction, while types 1-2 and 1-3 had 59.3% restriction in ROM. The stress of the cage in types 2-2 and 2-3 was approximately 20% lower than that in types 1-2 and 1-3 under all loading conditions in all models. The peak stresses at the screw-bone interface in types 2-2 and 2-3 were much lower (approximately 35%) than those in types 1-2 and 1-3 under lateral bending, while no significant differences were observed under flexion-extension and axial rotation. The peak stress on the L4 superior endplate was approximately 30 MPa and was not significantly different in all models under any loading condition.
Conclusions: Different regions of entry-exit screws induced multiple screw trajectories and influenced the stability and mechanical responses. However, different implantation angles did not. Considering the difficulty of implantation, the ipsilateral-contralateral trajectory in the lateral middle region of the VB can be optimal for in situ screw implantation in LLIF surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9251290 | PMC |
http://dx.doi.org/10.1111/os.13312 | DOI Listing |
Nature
January 2025
Key Laboratory of Growth Regulation and Translational Research of Zhejiang Province, School of Life Sciences, Westlake University, Hangzhou, China.
Argonaute proteins are categorized into AGO and PIWI clades. Across most animal species, AGO-clade proteins are widely expressed in various cell types, and regulate normal gene expression. By contrast, PIWI-clade proteins predominantly function during gametogenesis to suppress transposons and ensure fertility.
View Article and Find Full Text PDFOper Neurosurg (Hagerstown)
July 2024
Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany.
Background And Objective: A safe working trajectory is mandatory for spinal pathologies, especially in the midline, anterior to the spinal cord. For thoracic cerebrospinal fluid (CSF) leaks, we developed a minimally invasive keyhole fenestration. This study investigates the necessary bone removal for sufficient exposure of different leak types particularly regarding weight-bearing structures.
View Article and Find Full Text PDFMed Phys
January 2025
Center for Virtual Imaging Trial, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, Durham, North Carolina, USA.
Background: This Special Report summarizes the 2022, AAPM grand challenge on Truth-based CT image reconstruction.
Purpose: To provide an objective framework for evaluating CT reconstruction methods using virtual imaging resources consisting of a library of simulated CT projection images of a population of human models with various diseases.
Methods: Two hundred unique anthropomorphic, computational models were created with varied diseases consisting of 67 emphysema, 67 lung lesions, and 66 liver lesions.
Int J Exerc Sci
December 2024
College of Health Sciences, Department of Athletic Training and Clinical Nutrition, University of Kentucky, Lexington, KY, USA.
Physical activity (PA) has a wide range of health benefits. Children with high levels of social support are more likely to achieve adequate levels of PA. The purposes of this pilot study were to examine the impact of an after-school intervention on perceived peer and parental support among adolescent girls and to identify correlates of support to explore in future studies to increase PA.
View Article and Find Full Text PDFRen Fail
December 2025
State Key Laboratory of Traditional Chinese Medicine Syndrome, The First Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, China.
Background: While there are numerous benefits to tea consumption, its long-term impact on patients with chronic kidney disease (CKD) remains unclear.
Method: Our analysis included 17,575 individuals with CKD from an initial 45,019 participants in the National Health and Nutrition Examination Survey (NHANES) (1999-2018). Individuals with extreme dietary habits, pregnancy, or non-CKD conditions were excluded.