Background: Pelvic organ prolapse (POP) significantly impairs women's quality of life. The literature reports that nearly one in five women will require surgery in their lifetime, and nearly 40.6% involve anterior wall repair, specifically cystocele. Several techniques and surgical approaches have been used for cystocele management. These were performed by transvaginal and/or transabdominal approach and involved the use of native tissue or prosthesis. Nevertheless, since the transvaginal mesh ban recommended by the FDA and learned societies, autologous tissue repair has become the cornerstone of all vaginal prolapse surgery.

Case Presentation: We hereby present the case of a 71-year-old widow who had undergone three vaginal deliveries. The patient reported that she no longer had sexual intercourse. The preoperative functional signs observed included: stress urinary incontinence, urinary urgency, dysuria and disabling vaginal ball feeling. The management strategy chosen in consultation with the patient was a repair using autologous material via the vaginal route. The vaginal strips were passed through trans-obturator and retro pubic route allowed support of the bladder.

Conclusions: This technique using autologous material was easy, fast and inexpensive. It was developed on the basis of the TVT and TOT techniques and stood out for its tolerance and long-lasting functional effectiveness. It avoids all the complications due to polypropylene trans-vaginal prostheses that led to the banning of trans-vaginal mesh.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9160734PMC
http://dx.doi.org/10.1016/j.ijscr.2022.107198DOI Listing

Publication Analysis

Top Keywords

autologous material
8
vaginal
6
transvaginal transobturator
4
autologous
4
transobturator autologous
4
autologous vaginal
4
vaginal tape
4
tape cystocele
4
cystocele treatment
4
treatment uncommon
4

Similar Publications

Background: For patients with osteoporosis and rotator cuff tears, there is still no consensus on current treatment methods. The material, structure, and number of anchors have important effects on the repair outcome.

Purpose: To investigate the use of chitosan quaternary ammonium salt-coated nickel-titanium memory alloy (NTMA) anchors to treat rotator cuff injury in shoulders with osteoporosis in a rabbit osteoporosis model.

View Article and Find Full Text PDF

Introduction: Different Guided Tissue Regeneration (GTR) procedures, such as membranes, bone substitute materials, and Autologous Platelet Concentrates (APCs), have been applied after surgical root canal treatment (SRCT), which produce different outcomes. This study aimed to evaluate the impact of regenerative procedures on the healing process following SRCT.

Methods: A comprehensive search of PubMed, Embase, Scopus, Cochrane, and the Web of Science found Randomized Controlled Trials (RCTs) published until February 25, 2024.

View Article and Find Full Text PDF

Background: Nerve wraps composed of various autologous and bioengineered materials have been used to bolster nerve repair sites. In this study, we describe the novel use of autologous fascia nerve wraps (AFNW) as an adjunct to epineurial repair and evaluate their effect on inflammatory cytokine expression, intraneural collagen deposition and end-organ reinnervation in rats and use of AFNW in a patient case series.

Methods: Lewis rats received sciatic transection with repair either with or without AFNW, sciatic-to-common peroneal nerve transfer with or without AFNW, or sham surgery (n=14/group).

View Article and Find Full Text PDF

Background: This systematic review and meta-analysis aimed to assess the efficacy of autologous platelet concentrate (APCs) in comparison with coronally-advanced flap alone or in combination with connective tissue graft or other biomaterials or bioactive agents for root coverage (RC) of Miller's Class I and II gingival recession defects by measuring the keratinized mucosa width (KMW).

Materials And Methods: This systematic review and meta-analysis was conducted in accordance with the preferred reporting items for systematic reviews and meta-analysis guidelines. An electronic search of the literature was conducted in PubMed, EMBASE, Scopus, Cochrane, Web of Science, Magiran, Scientific Information Database, and Irandoc for randomized clinical trials (RCTs) that used APCs for RC in their intervention group.

View Article and Find Full Text PDF

Background: The gold standard of care for patients with severe peripheral nerve injury is autologous nerve grafting; however, autologous nerve grafts are usually limited for patients because of the limited number of autologous nerve sources and the loss of neurosensory sensation in the donor area, whereas allogeneic or xenografts are even more limited by immune rejection. Tissue-engineered peripheral nerve scaffolds, with the morphology and structure of natural nerves and complex biological signals, hold the most promise as ideal peripheral nerve "replacements".

Aim: To prepare allogenic peripheral nerve scaffolds using a low-toxicity decellularization method, and use human umbilical cord mesenchymal stem cells (hUC-MSCs) as seed cells to cultivate scaffold-cell complexes for the repair of injured peripheral nerves.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!