A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of sample density in prompt γ-ray analysis. | LitMetric

Effect of sample density in prompt γ-ray analysis.

Sci Rep

Nuclear Science and Engineering Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki, 319-1195, Japan.

Published: June 2022

A high-accuracy analytical method is broadly required to obtain reliable research results. Thus, prompt γ-ray analysis (PGA), one of the most accurate non-destructive analytical methods, has been employed in various fields. However, the measurement accuracy of PGA is also known to degrade in hydrogenous samples. The degradation is caused by variation in the measurement sensitivity (counts per milligram) following the change in neutron energy due to scattering with hydrogen nucleus. Number of scatterings is well known to depend on the hydrogen content in a sample. However, considering multiple scatterings, hydrogen density, which has not been taken into account as yet, may also lead to the accuracy degradation. Here, we show the effect of the hydrogen density in PGA by evaluating the measurement sensitivity of samples with the same hydrogen content and different densities. We find that the measurement sensitivity varies by more than 30% depending on the hydrogen density even at the same hydrogen content. The variation is a particularly serious problem for PGA requiring a few percent accuracy in most cases. Additionally, although the variation is apparently observed in hydrogenous samples, the similar phenomenon can occur in other nuclides with a large scattering cross section; it may affect nuclear cross-section measurements using neutrons in such fields as astrophysics and nuclear energy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9160239PMC
http://dx.doi.org/10.1038/s41598-022-08594-2DOI Listing

Publication Analysis

Top Keywords

measurement sensitivity
12
hydrogen content
12
hydrogen density
12
prompt γ-ray
8
γ-ray analysis
8
hydrogenous samples
8
hydrogen
7
sample density
4
density prompt
4
analysis high-accuracy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!