A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design and manufacture of a radiative cooler to measure the subambient cooling effect and cooling power. | LitMetric

The obscure theory of passive subambient daytime radiative cooling (PSDRC) was deduced in a more understandable way using an arithmetic formula rather than integro-differential equations. Based on two boundary conditions of the equations, an innovative radiative cooler was successfully developed to qualitatively observe PSDRC phenomena and quantitatively characterize the cooling effect and cooling power of radiative cooling coatings (RC coatings). The remarkable subambient temperature reduction over 4.0 °C was successfully achieved in a completely open environment without minimizing the parasitic conduction and convection from the ambient. Prominent PSDRC phenomena could even be observed in such an open environment on very cloudy days, which generally compromise the RC. A much more prominent subambient cooling depression of 10.0 °C was observed when a wind shield was employed to minimize the convection. With suppression of convection, the subambient daytime cooling effect on cloudy days was even more noticeable than that occurred on clear sunny days. The subambient cooling effect was still very remarkable even on clear sunny days in the winter. The average cooling power measured on a clear sunny day was 154.8 ± 9.7 W/m, corresponding to an average solar irradiance of 680 ± 90 W/m with a peak value of ∼820 W/m. Both the subambient RC effect and the cooling power measured under real weather conditions using the radiative cooler agreed excellently with the theoretical prediction, sufficiently demonstrating the great innovation, validity, and effectiveness of the device.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0087494DOI Listing

Publication Analysis

Top Keywords

subambient cooling
16
cooling power
16
radiative cooler
12
clear sunny
12
cooling
11
cooling cooling
8
subambient daytime
8
radiative cooling
8
psdrc phenomena
8
open environment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!