This retrospective review evaluated our institutions’ practice of administering low fixed-dose FEIBA (high (1000 units) or low dose (500 units) for an INR ≥ 5 or <5, respectively) for the management of warfarin-associated coagulopathies. The primary outcome was the percentage of patients who had a post-FEIBA INR ≤ 1.5. In the total population, 55.6% (10/18) of patients achieved a post-FEIBA INR ≤ 1.5. In the subgroup analysis, significantly more patients in the low dose FEIBA group achieved a post-FEIBA INR ≤ 1.5 compared to the high dose FEIBA group (71.4% vs. 45.5%, respectively, p < 0.001). In the post hoc analysis, there was a significant difference in the number of patients who achieved a post-FEIBA INR ≤ 1.5 when comparing those who received high dose FEIBA with a baseline INR 5−9.9 to those who received high dose FEIBA with a baseline INR ≥ 10 (60% vs. 33.3%, respectively, p < 0.001). The existing literature and our findings suggest that patients who present with lower baseline INR values and receive additional reversal agents are more likely to meet post-reversal INR goals. Current low fixed-dose protocols may be oversimplified and may need to be revised to provide larger fixed-doses.