Background And Objectives: Exchange transfusion is a valuable treatment option in sickle cell disease (SCD) and is preferred over simple transfusion as it removes abnormal haemoglobin S (HbS) levels and reduces complications. This meta-analysis aims to evaluate the efficacy and safety profile of automated red cell exchange (aRBX) procedure over manual red cell exchange transfusion (MET) in SCD patients.
Materials And Methods: A standard meta-analysis protocol was developed, and after performing a comprehensive literature search in PubMed/MEDLINE, Cochrane and International Clinical Trial Registry Platform (ICTRP), reviewers assessed eligibility and extracted data from nine relevant studies. A random effects model was used to estimate the pooled effect size calculated from the mean difference in HbS percentage, serum ferritin level and risk ratio for the adverse events. Quality assessment was done using the risk-of-bias assessment tool, and a summary of observations was prepared using standard Cochrane methodology with GradePro GDT.
Results: The random-model analysis revealed a mean difference of 4.10 (95% CI: -3.29-11.49; Z = 1.09; p = 0.28) for HbS percentage, mean difference of 435.29 (95% CI: -73.74-944.32; Z = 1.68; p = 0.09) for serum ferritin and pooled risk ratio of 1.35 (95% CI: 0.63-2.87; Z = 0.77; p = 0.44) for adverse events.
Conclusion: This meta-analysis did not reveal any significant benefit of aRBX in reducing HbS percentage and attenuating the serum ferritin level when compared with MET. There was also no significant increased risk of adverse events detected in association with aRBX.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/vox.13288 | DOI Listing |
Best Pract Res Clin Anaesthesiol
December 2023
Department of Anesthesiology and Perioperative Medicine, The University of Texas, MD Anderson Cancer Center, USA; Anesthesiology and Surgical Oncology Research Group, USA. Electronic address:
Patients with cancer who receive allogeneic red blood cell transfusions are at risk of adverse reactions of varying severity. One of these reactions is immunomodulation, also known as transfusion-related immunomodulation. With the exact mechanism of transfusion related immunomodulation being unclear, storage lesions (both the cellular and cytokine component) are considered a major contributor.
View Article and Find Full Text PDFBest Pract Res Clin Anaesthesiol
December 2023
Department of Anesthesia, St. Michael's Hospital, Unity Health Toronto, Toronto, Ontario, Canada; Department of Anesthesiology and Pain Medicine, University of Toronto, Toronto, Ontario, Canada; Department of Physiology, University of Toronto, Toronto, Ontario, Canada; Li Ka Shing Knowledge Institute of St. Michael's Hospital, Unity Health Toronto, Toronto, Ontario, Canada; Department of Pharmacology and Toxicology, University of Toronto, Toronto, Ontario, Canada; Institute of Medical Sciences, University of Toronto, Toronto, Ontario, Canada. Electronic address:
Anemia and red blood cell transfusion are associated with adverse outcomes. Large randomized trials have demonstrated that restrictive transfusion strategies can safely reduce patient exposure to transfusion, forming a foundational pillar of patient blood management. The restrictive transfusion thresholds in these trials ranged from 7 to 8 g/dL for different populations and this variability is reflected in recent guideline recommendations for transfusion triggers.
View Article and Find Full Text PDFAfr J Reprod Health
December 2024
Department of Cardiology, The First Affiliated Hospital,Hengyang Medical School, University of South China.
Anaemia is a common phenomenon in patients with malignant gynecological tumors. The occurrence of anaemia in the perioperative period leads to an increased probability of blood transfusion, increased surgical complications,poor wound healing, prolonged hospitalization, increased medical costs, and increased mortality. Intravenous iron, which is known for its rapid onset and lack of gastrointestinal side effects, has become increasingly prevalent in clinical practice.
View Article and Find Full Text PDFJ Biomed Mater Res A
January 2025
Faculty of Materials Science and Engineering, Warsaw University of Technology, Warsaw, Poland.
Bone tissue regeneration can be affected by various architectonical features of 3D porous scaffold, for example, pore size and shape, strut size, curvature, or porosity. However, the design of additively manufactured structures studied so far was based on uniform geometrical figures and unit cell structures, which often do not resemble the natural architecture of cancellous bone. Therefore, the aim of this study was to investigate the effect of architectonical features of additively manufactured (aka 3D printed) titanium scaffolds designed based on microtomographic scans of fragments of human femurs of individuals of different ages on in vitro response of human bone-derived mesenchymal stem cells (hMSC).
View Article and Find Full Text PDFFront Microbiol
December 2024
Faculty of Health and Life Sciences, INTI International University, Nilai, Malaysia.
Introduction: Lactic acid bacteria are prized for their probiotic benefits and gut health improvements. This study assessed five LAB isolates from Neera, with RAMULAB51 (, GenBank ON171686.1) standing out for its high hydrophobicity, auto-aggregation, antimicrobial activity, and enzyme inhibition.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!