A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Visual and instrumental coverage error of two dental shade guides: an in vivo study. | LitMetric

Visual and instrumental coverage error of two dental shade guides: an in vivo study.

Clin Oral Investig

Department of Optics, Faculty of Science, University of Granada, Campus de Fuente Nueva, Edificio Mecenas, s/n 18071, ibs-Granada, Granada, Spain.

Published: September 2022

Objectives: This study aims to evaluate in vivo the color agreement between natural teeth and dental shade guides by means of visual and instrumental coverage error ([Formula: see text]) index.

Materials And Methods: The color of the middle third of 735 incisors was visually determined by two evaluators using the Vita Classical (VC) and Vita 3D Master (V3DM) shade guides. The color match between the natural tooth and the shade tab was rated as poor (P), good (G), or optimum (O) by each observer. CIE color coordinates of the target teeth and shade tabs of VC and V3DM were instrumentally measured using a clinical spectrophotometer. Visual ([Formula: see text]) and instrumental ([Formula: see text]) coverage error indexes were computed using CIELAB and CIEDE2000 metrics for both shade guides. For [Formula: see text] calculation, only the concordant inter-observer determination on tooth shade rated as O-O or O-G was used. The results were evaluated using perceptibility (PT, [Formula: see text]= 1.2, [Formula: see text]= 0.8) and acceptability (AT, [Formula: see text]= 2.7, [Formula: see text]= 1.8) color thresholds for dentistry.

Results: VC and V3DM exhibited [Formula: see text] (2.5, 3.2, and 3.2, 2.7 CIELAB units; 1.9, 2.3, and 2.8, 2.4 CIEDE2000 units, respectively, for O-O and O-G match) and [Formula: see text] (4.7, 4.8, and 4.1, 4.6 CIELAB units; 3.3, 3.4, and 3.4, 3.6 CIEDE2000 units, respectively, for O-O and O-G match) values greater than 50:50% AT for both color difference formulas. [Formula: see text] contributes more than 50% (53.2-82.4% range) to the [Formula: see text] value. This contribution depends on the shade guide used and the quality of the visual rating.

Conclusions: The evaluated shade guides exhibited visual coverage errors above acceptability thresholds, largely due to the contribution of the instrumental coverage error to the visual coverage error.

Clinical Relevance: It necessary to further improve commercially available dental shade guides to facilitate achievement of satisfactory esthetics results in clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9474559PMC
http://dx.doi.org/10.1007/s00784-022-04556-0DOI Listing

Publication Analysis

Top Keywords

[formula text]
32
shade guides
24
coverage error
16
[formula text]=
16
instrumental coverage
12
dental shade
12
[formula
12
o-o o-g
12
shade
10
visual instrumental
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!