AI Article Synopsis

  • Transcatheter aortic valve implantation (TAVI) using a percutaneous axillary approach is being evaluated for its safety and effectiveness compared to traditional surgical access.
  • An international study analyzed data from 432 patients, revealing that while the percutaneous approach had a higher rate of primary hemostasis failure, it led to shorter hospital stays and lower risks of major complications.
  • The findings suggest that percutaneous axillary access is as effective or potentially superior to surgical access for TAVI, especially for patients who cannot use the femoral approach.

Article Abstract

Background: Transcatheter aortic valve implantation (TAVI) is an established management strategy for severe aortic valve stenosis. Percutaneous axillary approach for TAVI holds the promise of improving safety without jeopardizing effectiveness in comparison to surgical access. We aimed at appraising the comparative effectiveness of percutaneous vs. surgical axillary approaches for TAVI.

Methods: We performed an international retrospective observational study using de-identified details on baseline, procedural, and 1-month follow-up features. Valve Academic Research Consortium (VARC)-3 criteria were applied throughout. Outcomes of interest were clinical events up to 1 month of follow-up, compared with unadjusted and propensity score-adjusted analyses.

Results: A total of 432 patients were included, 189 (43.8%) receiving surgical access, and 243 (56.2%) undergoing percutaneous access. Primary hemostasis failure was more common in the percutaneous group (13.2% vs. 4.2%, P<0.001), leading to more common use of covered stent implantation (13.2% vs. 3.7%, P<0.001). Irrespectively, percutaneous access was associated with shorter hospital stay (-2.6 days [95% confidence interval: -5.0; -0.1], P=0.038), a lower risk of major adverse events (a composite of death, myocardial infarction, stroke, type 3 bleeding, and major access-site related complication; odds ratio=0.44 [0.21; 0.95], P=0.036), major access-site non-vascular complications (odds ratio=0.21 [0.06; 0.77], P=0.018), and brachial plexus impairment (odds ratio=0.16 [0.03; 0.76], P=0.021), and shorter hospital stay (-2.6 days [-5.0; -0.1], P=0.038).

Conclusions: Percutaneous axillary access provides similar or better results than surgical access in patients undergoing TAVI with absolute or relative contraindications to femoral access.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S0031-0808.22.04750-4DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
percutaneous surgical
8
surgical axillary
8
transcatheter aortic
8
valve implantation
8
surgical access
8
percutaneous
5
access
4
axillary access
4
access transcatheter
4

Similar Publications

Differential determinants and prognostic value of aortic valve sclerosis over carotid atherosclerosis.

Int J Cardiol

January 2025

Division of Cardiology, Heart Center, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea. Electronic address:

Background: Aortic valve sclerosis (AVS) is a progressive atherosclerotic disease associated with future cardiovascular events (CVE). However, whether its development and prognostic value are independent of arterial atherosclerosis has not been thoroughly investigated. We evaluated the determinants and prognostic value of AVS in conjunction with carotid atherosclerosis.

View Article and Find Full Text PDF

Background: Since patients with congenital heart defects (CHD) frequently require life-long medical care and repeat invasive treatment, radiation exposure during interventional procedures is a relevant issue concerning potential radiation related risks. Therefore, an analysis on radiation data from the German Registry for Cardiac Operations and Interventions in patients with CHD was performed.

Methods: From January 2012 until December 2020 a total of 28,374 cardiac catheter interventions were recorded.

View Article and Find Full Text PDF

Background And Objective: In clinical practice, valve-sparing aortic root replacement surgery primarily addresses left ventricular dysfunction in patients due to severe aortic regurgitation, but there is controversy regarding the choice of surgical technique. In order to investigate which type of valve-sparing aortic root replacement surgeries can achieve better blood flow conditions, this study examines the impact of changes in the geometric morphology of the aortic root on the hemodynamic environment through numerical simulation.

Methods: An idealized model of the aortic root was established based on data obtained from clinical measurements, including using the model of the aortic root without significant lesions as the control group (Model C), while using surgical models of leaflet reimplantation with tubular graft (Model T), leaflet reimplantation with Valsalva graft (Model V), and the Florida sleeve procedure (Model F) as the experimental groups.

View Article and Find Full Text PDF

Sex Differences in Aortic Valve Inflammation and Remodeling in Chronic Severe Aortic Regurgitation.

Am J Physiol Heart Circ Physiol

January 2025

Cardiovascular Translational Research. Navarrabiomed (Fundación Miguel Servet), Instituto de Investigación Sanitaria de Navarra (IdiSNA), Hospital Universitario de Navarra (HUN), Universidad Pública de Navarra (UPNA), Pamplona, Spain.

Aortic regurgitation (AR) is more prevalent in male, although cellular and molecular mechanisms underlying the sex differences in prevalence and pathophysiology are unknown. This study evaluates the impact of sex on aortic valve (AV) inflammation and remodeling as well as the cellular differences in valvular interstitial cells (VICs) and valvular endothelial cells (VECs) in patients with AR. A total of 144 patients (27.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!