A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cooling strategies for firefighters: Effects on physiological, physical, and visuo-motor outcomes following fire-fighting tasks in the heat. | LitMetric

Objectives: Due to the nature of firefighting, most effective cooling interventions to reduce heat strain and optimise performance are not practically viable. This study quantified the effects of two practical cooling strategies, co-designed with subject-matter experts, on physiological strain and physical, perceptual, and visuo-motor performance during simulated firefighting in the heat.

Design: Randomised cross-over.

Methods: On three occasions 14 firefighters completed an 80-min simulation in a hot-humid environment (32.0[0.9]°C, 59[3]%RH) including two 20-min firefighting tasks in full protective clothing, each followed by 20-min seated recovery. Recovery involved removal of protective clothing and one of three interventions - control (CON; ambient-temperature water consumption), basic (BASIC; cool-water consumption, ambient-forearm immersion/towels, fan), and advanced (ADV; ice-slushy consumption, cool-forearm immersion/ice packs, misting-fan). Thermal (core temperature) and cardiovascular (heart rate, arterial pressure) responses were measured throughout, whilst physical (handgrip/balance), visuo-motor (reaction time/memory recall) and perceptual (fatigue/thermal sensation/comfort) measures were assessed pre- and post-trial.

Results: Compared to CON, core temperature was lower in BASIC and ADV following the second task (ADV: 37.7[0.4]; BASIC: 38.0[0.4]; CON: 38.3[0.4]°C) and recovery protocol (ADV: 37.5[0.3]; BASIC: 37.7 [0.3] CON: 38.3[0.4]°C). This was paralleled by lowered heart rate, rate pressure product, and thermal sensation following the recovery protocols, in the ADV and BASIC condition compared to CON (p < .05). No physical or visuo-motor outcomes differed significantly between conditions.

Conclusion: Whilst these observations need to be extended to field conditions, our findings demonstrate that two novel cooling interventions developed in collaboration with subject-matter experts offered benefits for reducing thermal strain and optimising firefighter safety.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtherbio.2022.103236DOI Listing

Publication Analysis

Top Keywords

cooling strategies
8
protective clothing
8
core temperature
8
heart rate
8
compared con
8
con 383[04]°c
8
basic
6
con
5
adv
5
strategies firefighters
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!