A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Carrying Position-Independent Ensemble Machine Learning Step-Counting Algorithm for Smartphones. | LitMetric

Current step-count estimation techniques use either an accelerometer or gyroscope sensors to calculate the number of steps. However, because of smartphones unfixed placement and direction, their accuracy is insufficient. It is necessary to consider the impact of the carrying position on the accuracy of the pedometer algorithm, because of people carry their smartphones in various positions. Therefore, this study proposes a carrying-position independent ensemble step-counting algorithm suitable for unconstrained smartphones in different carrying positions. The proposed ensemble algorithm comprises a classification algorithm that identifies the carrying position of the smartphone, and a regression algorithm that considers the identified carrying position and calculates the number of steps. Furthermore, a data acquisition system that collects (i) label data in the form of the number of steps estimated from the Force Sensitive Resistor (FSR) sensors, and (ii) input data in the form of the three-axis acceleration data obtained from the smartphones is also proposed. The obtained data were used to allow the machine learning algorithms to fit the signal features of the different carrying positions. The reliability of the proposed ensemble algorithms, comprising a random forest classifier and a regression model, was comparatively evaluated with a commercial pedometer application. The results indicated that the proposed ensemble algorithm provides higher accuracy, ranging from 98.1% to 98.8%, at self-paced walking speed than the commercial pedometer application, and the machine learning-based ensemble algorithms can effectively and accurately predict step counts under different smart phone carrying positions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9144748PMC
http://dx.doi.org/10.3390/s22103736DOI Listing

Publication Analysis

Top Keywords

number steps
12
carrying position
12
carrying positions
12
proposed ensemble
12
machine learning
8
step-counting algorithm
8
ensemble algorithm
8
data form
8
ensemble algorithms
8
commercial pedometer
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!