Recently, a renewable five-membered lactone containing citronellol (HBO-citro) was synthesized from levoglucosenone (LGO). A one-pot two-step pathway was then developed to produce a mixture of 5- and 6-membered Lactol-citro molecules (5ML and 6ML, respectively) from HBO-citro. Proton nuclear magnetic resonance (H NMR) of a mixture of 5ML and 6ML at varying temperatures showed that the chemical shifts of the hydroxyls, as well as the 5ML:6ML ratio, are temperature-dependent. Indeed, a high temperature, such as 65 °C, led to an up-field shielding of the hydroxyl protons as well as a drop in the 5ML:6ML ratio. The monomers 5ML and 6ML were then engaged in polycondensation reactions involving diacyl chlorides. Renewable copolyesters with low glass transition temperatures (as low as -67 °C) and cross-linked citronellol chains were prepared. The polymers were then hydrolyzed using a commercial lipase from (Lipopan 50 BG). A higher degradation rate was found for the polymers prepared using Lactol-citro molecules, compared to those obtained by the polycondensation reactions of diacyl chlorides with Triol-citro-a monomer recently obtained by the selective reduction of HBO-citro.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9146931 | PMC |
http://dx.doi.org/10.3390/polym14102082 | DOI Listing |
Int J Stroke
December 2024
Department of Clinical Neurosciences, University of Calgary, Calgary, Canada.
Antioxidants (Basel)
June 2024
Department of Medical, Surgical and Advanced Technologies "G.F. Ingrassia", Hygiene and Public Health, University of Catania, Via Santa Sofia 73, 95123 Catania, Italy.
Exaggerated clot induces venous thrombosis (VTE); oxidative stress (OxS) can to be postulated as additional risk factor. This study evaluates firstly OxS by measuring surrogate biomarkers (malondialdehyde-MDA, 4-hydroxinonenal-4-HNE, superoxide desmutase enzyme (SOD)), secondly the iron (Fe) plasma level and thirdly the hepcidin protein (Hep) level in patients with VTE. A case control study was performed enrolling twenty hospitalized patients and an equal number of healthy individuals.
View Article and Find Full Text PDFJ Perioper Pract
June 2024
Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, SC, USA.
Introduction: Nasal and sinus surgery, especially using endoscopy, relies upon adequate haemostasis to be safe and effective. Often other haemostatic methods, such as cautery are not viable, and other methods must be employed. This study examines the effectiveness of dexmedetomidine in controlled hypotension and for surgical field visibility in endoscopic sinus surgery and other nasal surgeries.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
June 2024
The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan Province, 450052, China.
To assess the impact of low-dose contrast media (CM) injection protocol with deep learning image reconstruction (DLIR) algorithm on image quality in coronary CT angiography (CCTA). In this prospective study, patients underwent CCTA were prospectively and randomly assigned to three groups with different contrast volume protocols (at 320mgI/mL concentration and constant flow rate of 5ml/s). After pairing basic information, 210 patients were enrolled in this study: Group A, 0.
View Article and Find Full Text PDFChronic Obstr Pulm Dis
April 2023
Division of Pulmonary, Critical Care and Sleep Medicine, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts, United States.
Rationale: Although physical activity is strongly encouraged for patients with chronic obstructive pulmonary disease (COPD), it is unknown if physical activity affects daily exposure to air pollution, or whether it attenuates or exacerbates the effects of pollution on the airways among adults with COPD.
Methods: Thirty former smokers with moderate-to-severe COPD in Boston were followed for 4 non-consecutive months in different seasons. We assessed daily lung function (forced expiratory volume in 1 second [FEV] and forced vital capacity [FVC]), prior-day personal pollutant exposure measured by portable air quality monitors (fine particulate matter [PM] nitrogen oxide [NO], and ozone [O]), and daily step count.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!