HO-related metabolites are essential indicators in clinical diagnosis because the accumulation of such reactive oxygen species could cause the risk of cardiovascular disease. Herein, we reported an electrochemical sensor to determine HO and glucose. The pyrroloquinoline skeleton containing molecules (PQT) were used as the electrocatalyst and the gold cavity array (GCA) electrodes as the supporting electrode. The GCA electrode was fabricated by electrodeposition using high-ordered two-dimensional polystyrene spheres as the template. The strong absorbability of iodide ions (I) displaced adventitious materials from the metal surface and the I monolayer was subsequently removed by electrochemical oxidation to get a clean electrode surface. PQT molecules were firmly immobilized on the GCA electrode and performed an excellent electrocatalytic effect on HO/glucose detection, manifested by a small overpotential and a significantly increased reduction current. A good linear correlation was observed over a wide range of 0.2 μmol/L-1.0 mmol/L with the limit of detection of 0.05 μmol/L. Moreover, the sensor can realize sensitive, accurate, and the highly selective detection of actual samples, proving its application prospect in clinical diagnosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9144773 | PMC |
http://dx.doi.org/10.3390/nano12101770 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!