The aim of the study was to determine the influence of a key treatment plan and beam parameters on overall dose distribution and on doses in organs laying in further distance from the target during prostate SBRT. Multiple representative treatment plans (n = 12) for TrueBeam and CyberKnife were prepared and evaluated. Nontarget doses were measured with anionization chamber, in a quasi-humanoid phantom at four sites corresponding to the intestines, right lung, thyroid, and head. The following parameters were modified: radiotherapy technique, presence or not of a flattening filter, degree of modulation, and use or not of jaw tracking function for TrueBeam and beam orientation set-up, optimization techniques, and number of MUs for CyberKnife. After usual optimization doses in intestines (near the target) were 0.73% and 0.76%, in head (farthest from target) 0.05% and 0.19% for TrueBeam and CyberKnife, respectively. For TrueBeam the highest peripheral (head, thyroid, lung) doses occurred for the VMAT with the flattening filter while the lowest for 3DCRT. For CyberKnife the highest doses were for gantry with caudal direction beams blocked (gantry close to OARs) while the lowest was the low modulated VOLO optimization technique. The easiest method to reduce peripheral doses was to combine FFF with jaw tracking and reducing monitor units at TrueBeam and to avoid gantry position close to OARs together with reduction of monitor units at CyberKnife, respectively. The presented strategies allowed to significantly reduce out-of-field and nontarget doses during prostate radiotherapy delivered with TrueBeam and CyberKnife. A different approach was required to reduce peripheral doses because of the difference in dose delivery techniques: non-coplanar using CyberKnife and coplanar using TrueBeam, respectively.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9146748 | PMC |
http://dx.doi.org/10.3390/life12050628 | DOI Listing |
Pract Radiat Oncol
November 2023
Department of Medical Physics, Guy's and St Thomas' NHS Foundation Trust, School of Biomedical Engineering & Imaging Sciences, King's College London, London, United Kingdom.
Purpose: Stereotactic radiosurgery treatment delivery can be performed with a range of devices, each of which have evolved over recent years. We sought to evaluate the differences in performance of contemporary stereotactic radiosurgery platforms and also to compare them with earlier platform iterations from a previous benchmarking study.
Methods And Materials: The following platforms were selected as "state of the art" in 2022: Gamma Knife Icon (GK), CyberKnife S7 (CK), Brainlab Elements (Elekta VersaHD and Varian TrueBeam), Varian Edge with HyperArc (HA), and Zap-X.
Cancer Radiother
April 2023
Radiation Therapy Department, Institut de cancérologie de Lorraine-centre Alexis-Vautrin, Vandœuvre-lès-Nancy, France.
Appl Radiat Isot
February 2023
Istanbul University, Faculty of Science, Department of Physics, Istanbul, Turkey. Electronic address:
As the Stereotactic Body Radiotherapy (SBRT) approach began to increase in treating patients with localized prostate cancer, it became necessary to investigate which methods used in practice were better. The aim of this study is to perform a dosimetric comparison of the advantages and disadvantages of SBRT treatments for localized prostate cancer delivered by CyberKnife (CK) and Varian Truebeam STX (FF and FFF). Seventeen intermediate and high-risk patients with localized prostate cancer were included in the study.
View Article and Find Full Text PDFLife (Basel)
April 2022
Electroradiology Department, Poznan University of Medical Sciences, 61-866 Poznan, Poland.
The aim of the study was to determine the influence of a key treatment plan and beam parameters on overall dose distribution and on doses in organs laying in further distance from the target during prostate SBRT. Multiple representative treatment plans (n = 12) for TrueBeam and CyberKnife were prepared and evaluated. Nontarget doses were measured with anionization chamber, in a quasi-humanoid phantom at four sites corresponding to the intestines, right lung, thyroid, and head.
View Article and Find Full Text PDFMed Phys
February 2022
ACRF Image X Institute, The University of Sydney, Sydney, New South Wales, Australia.
Purpose: Lung stereotactic ablative body radiotherapy (SABR) is a radiation therapy success story with level 1 evidence demonstrating its efficacy. To provide real-time respiratory motion management for lung SABR, several commercial and preclinical markerless lung target tracking (MLTT) approaches have been developed. However, these approaches have yet to be benchmarked using a common measurement methodology.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!