A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Stabilization of the Distal Radioulnar Joint with or without Triangular Fibrocartilage Complex Tear by an External Wrist Band Brace: A Cadaveric Study. | LitMetric

The purpose of this study was to investigate whether a watch-shaped external wrist band brace improves distal radioulnar joint (DRUJ) stability. Seven fresh cadaveric arms were used. Using a customized testing system, volar and dorsal translation forces were applied to the radius externally while the ulna was fixed. The test was performed with the forearm in neutral, 60° pronated, and 60° supinated positions, once without the brace and once with the brace applied. In each condition, the amount of translation was measured. Then, the triangular fibrocartilage complex (TFCC) was detached from the ulnar styloid process and the fovea ulnaris, and the same tests were performed again. Detachment of the TFCC significantly increased volar and dorsal translations in all forearm rotations compared to the intact condition (p < 0.05), except for the pronated dorsal translation of the radius (p = 0.091). Brace application significantly reduced volar and dorsal translations in all forearm rotations both in intact specimens and in TFCC-detached specimens (p < 0.05), except for pronated volar and dorsal translations in TFCC-detached specimens (p = 0.101 and p = 0.131, respectively). With the brace applied, the TFCC-detached specimens showed no significant difference in volar or dorsal translation in all forearm rotations compared to the intact specimens (p > 0.05). The external wrist band brace improved DRUJ stability in both normal and TFCC-torn wrists and reduced the DRUJ instability caused by TFCC tear to a near-normal level.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9142000PMC
http://dx.doi.org/10.3390/healthcare10050828DOI Listing

Publication Analysis

Top Keywords

volar dorsal
20
external wrist
12
wrist band
12
band brace
12
dorsal translation
12
dorsal translations
12
forearm rotations
12
tfcc-detached specimens
12
distal radioulnar
8
radioulnar joint
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!