In China, low-pass whole-genome sequencing (low-pass WGS) is emerging as an alternative diagnostic test to detect copy number variants (CNVs). This survey aimed to study the laboratory practice, service quality, and case volumes of low-pass WGS-based CNV analysis among national accredited Chinese tertiary hospitals that have routinely applied low-pass WGS for more than a year and that have been certified in next-generation sequencing (NGS) clinical applications for more than three years. The questionnaire focused on (1) the composition of patients' referral indications for testing and annual case volumes; (2) the capacity of conducting laboratory assays, bioinformatic analyses, and reporting; (3) the sequencing platforms and parameters utilized; and (4) CNV nomenclature in reports. Participants were required to respond based on their routine laboratory practices and data audited in a 12-month period from February 2019 to January 2020. Overall, 24 participants representing 24 tertiary referral hospitals from 21 provincial administrative regions in China returned the questionnaires. Excluding three hospitals routinely applying low-pass WGS for non-invasive prenatal testing (NIPT) only, the analysis only focused on the data submitted by the rest 21 hospitals. These hospitals applied low-pass WGS-based CNV analysis for four primary applications: high-risk pregnancies, spontaneous abortions, couples with adverse pregnancy history, and children with congenital birth defects. The overall estimated annual sample volume was over 36,000 cases. The survey results showed that the most commonly reported detection limit for CNV size (resolution) was 100 kb; however, the sequencing methods utilized by the participants were variable (single-end: 61.90%, 13/21; paired-end: 28.57%, 6/21; both: 9.52%, 2/21). The diversity was also reflected in the sequencing parameters: the mean read count was 13.75 million reads/case (95% CI, 9.91-17.60) and the read-length median was 65 bp (95% CI, 75.17-104.83). To assess further the compliance of the CNV reporting nomenclature according to the 2016 edition of International System for Human Cytogenomics Nomenclature (ISCN 2016), a scoring metric was applied and yielded responses from 19 hospitals; the mean compliance score was 7.79 out of 10 points (95% CI, 6.78-8.80). Our results indicated that the low-pass WGS-based CNV analysis service is in great demand in China. From a quality control perspective, challenges remain regarding the establishment of standard criteria for low-pass WGS-based CNV analysis and data reporting formats. In summary, the low-pass WGS-based method is becoming a common diagnostic approach, transforming the possibilities for genetic diagnoses for patients in China.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9139561PMC
http://dx.doi.org/10.3390/diagnostics12051098DOI Listing

Publication Analysis

Top Keywords

low-pass wgs-based
20
wgs-based cnv
16
cnv analysis
16
low-pass wgs
12
low-pass
9
low-pass whole-genome
8
copy number
8
chinese tertiary
8
tertiary hospitals
8
case volumes
8

Similar Publications

Article Synopsis
  • The study investigates whether longer telomere length in embryos at the blastocyst stage is linked to better survival rates after frozen-thawed embryo transfer (FET).
  • It finds that telomere length (TL) is a critical factor affecting implantation likelihood, as assessed using low-pass whole genome sequencing data from embryos subjected to preimplantation genetic testing.
  • Although initially 965 blastocysts were considered, only 216 underwent FET, highlighting the need for further exploration into factors influencing embryo viability and implantation success.
View Article and Find Full Text PDF

Genome-wide sequencing allows for prediction of clinical treatment responses and outcomes by estimating genomic status. Here, we developed Genomic Status scan (GSscan), a long short-term memory (LSTM)-based deep-learning framework, which utilizes low-pass whole genome sequencing (WGS) data to capture genomic instability-related features. In this study, GSscan directly surveys homologous recombination deficiency (HRD) status independent of other existing biomarkers.

View Article and Find Full Text PDF

Single-cell low-pass whole genome sequencing accurately detects circulating tumor cells for liquid biopsy-based multi-cancer diagnosis.

NPJ Precis Oncol

February 2024

Key Laboratory of Whole-Period Monitoring and Precise Intervention of Digestive Cancer (SMHC), Minhang Hospital and Shanghai Key Laboratory of Medical Epigenetics, Institutes of Biomedical Sciences, Fudan University, Shanghai, 200032, China.

Accurate detection of circulating tumor cells (CTCs) in blood and non-blood body fluids enables generation of deterministic cancer diagnosis and represent a less invasive and safer liquid biopsy approach. Although genomic alternations have been widely used in circulating tumor DNA (ctDNA) analysis, studies on cell-based genomic alternations profiling for CTC detection are rare due to major technical limitations in single-cell whole genome sequencing (WGS) including low throughput, low accuracy and high cost. We report a single-cell low-pass WGS-based protocol (scMet-Seq) for sensitive and accurate CTC detection by combining a metabolic function-associated marker Hexokinase 2 (HK2) and a Tn5 transposome-based WGS method with improved cell fixation strategy.

View Article and Find Full Text PDF

Copy number aberrations in circulating tumor DNA enables prognosis prediction and molecular characterization of breast cancer.

J Natl Cancer Inst

September 2023

Division of Medical Oncology, Department of Internal Medicine, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, Republic of Korea.

Background: Low-pass whole-genome sequencing (LP-WGS)-based circulating tumor DNA (ctDNA) analysis is a versatile tool for somatic copy number aberration (CNA) detection, and this study aims to explore its clinical implication in breast cancer.

Methods: We analyzed LP-WGS ctDNA data from 207 metastatic breast cancer (MBC) patients to explore prognostic value of ctDNA CNA burden and validated it in 465 stage II-III triple-negative breast cancer (TNBC) patients who received neoadjuvant chemotherapy in phase III PEARLY trial (NCT02441933). The clinical implication of locus level LP-WGS ctDNA profiling was further evaluated.

View Article and Find Full Text PDF

In China, low-pass whole-genome sequencing (low-pass WGS) is emerging as an alternative diagnostic test to detect copy number variants (CNVs). This survey aimed to study the laboratory practice, service quality, and case volumes of low-pass WGS-based CNV analysis among national accredited Chinese tertiary hospitals that have routinely applied low-pass WGS for more than a year and that have been certified in next-generation sequencing (NGS) clinical applications for more than three years. The questionnaire focused on (1) the composition of patients' referral indications for testing and annual case volumes; (2) the capacity of conducting laboratory assays, bioinformatic analyses, and reporting; (3) the sequencing platforms and parameters utilized; and (4) CNV nomenclature in reports.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!