A peptide aptamer based electrochemical amperometric sensor for sensitive L-glutamate detection.

Bioelectrochemistry

Hunan Provincial Key Laboratory of Animal Nutritional Physiology and Metabolic Process, Key Laboratory of Agro-ecological Processes in Subtropical Region, Institute of Subtropical Agriculture, Chinese Academy of Sciences, National Engineering Laboratory for Pollution Control and Waste Utilization in Livestock and Poultry Production, Hunan Provincial Engineering Research Canter for Healthy Livestock and Poultry Production, Scientific Observational and Experimental Station of Animal Nutrition and Feed Science in South-Central, Ministry of Agriculture, Changsha, Hunan 410125, PR China. Electronic address:

Published: August 2022

L-glutamate (L-Glu) has gained much attention owing to its contribution to the umami taste and it plays important roles in the central nervous system. Herein, an enzyme-free amperometric biosensor based on a peptide possessing an electroactive ferrocene linker as ferrocene-Gly-Gly-Gly-Gly-Ile- Pro-Val-Tyr-Cys-Gly-Leu-Ile-Gly-Gly-Gly-Gly-Lys-(CH)- thioctic acid self- assembled on gold electrode was designed and fabricated for specific determination of L-Glu. The biosensor was characterised via cyclic voltammetry, electrochemical impedance spectroscopy, atomic force microscopy and scanning electron microscopy. The biosensor showed optimum response within 200 s at 0.10 V in phosphate-buffered saline. Moreover, the biosensor exhibited excellent sensitivity and a low detection limit of 1.00 × 10 M. The sensitivity at an L-Glu concentration of 1.00 × 10 M - 1.00 × 10 M was 0.1572 μA/M, and that at an L-Glu concentration of 1.00 × 10 M - 1.00 × 10 M was 0.0293 μA/M. The peptide-based biosensor had excellent specificity and a wider linear range. The relative standard deviation of the L-Glu concentrations measured by the biosensor in a hundred-fold dilution of mouse serum samples was less than 5.00% compared with the high-performance liquid chromatography results, and the recovery rate of L-Glu was from 93.32% to 105.15%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bioelechem.2022.108165DOI Listing

Publication Analysis

Top Keywords

l-glu concentration
8
concentration 100 × 10
8
100 × 10 100 × 10
8
l-glu
6
biosensor
6
100 × 10
5
peptide aptamer
4
aptamer based
4
based electrochemical
4
electrochemical amperometric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!