A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pilot Study of Polymerization Dynamics in nMAG Dose Gel. | LitMetric

The essential component of modern radiation therapy is the application of steep dose gradients during patient treatment in order to maximize the radiation dose to the target volume and protect neighboring heathy tissues. However, volumetric dose distribution in an irradiated target is still a bottleneck of dose verification in modern radiotherapy. Dose gels are almost the only known dosimetry tool which allows for the evaluation of dose distribution in the irradiated volume due to gel's polymerization upon irradiation. The accuracy of dose gel dosimetry has its own obstacle, which is related to the continuation of the gel's polymerization after the radiation treatment procedure is finished. In this article, a method to monitor the polymerization dynamics of dose gels in real-time is proposed using a modified optical spectrometry system. Using the proposed method, the changes of the optical characteristics of irradiated nMAG dose gels in situ were assessed. The investigation revealed that the detectable polymerization in dose gel proceeds up to 6 h after irradiation. This time is significantly shorter compared with a commonly recommended 24 h waiting time allocated for polymer gel to settle. It was also found that dose rate significantly influences the temporal response of the nMAG dosimeter. By increasing the irradiation dose rate by a factor of 2, the time needed for the polymerization process to settle was increased by 22%. Identification of the gel's post-irradiation polymerization time interval and its dependence on irradiation parameters will contribute to more accurate dose verification using dose gel dosimetry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9140482PMC
http://dx.doi.org/10.3390/gels8050288DOI Listing

Publication Analysis

Top Keywords

dose gel
16
dose
15
dose gels
12
polymerization dynamics
8
nmag dose
8
dose distribution
8
distribution irradiated
8
dose verification
8
gel's polymerization
8
gel dosimetry
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!