Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
(1) Background: Dermal fillers are commonly used in aesthetic practice and their rheological characterization is of much interest today, as well as the stability study of the finished formula against external stimuli of a different nature (biological and physicochemical). Rheological tools have been exploited to characterize the physiochemical behaviour of a hyaluronic acid (HA) based dermal filler subjected to different thermal conditions over time. The collected results provide an index of its rheological stability. (2) Methods: After a preliminary Amplitude sweep test, the Frequency sweep test was performed in order to study the stability of a HA dermal filler cross-linked with Polyethylene Glycol Diglycidyl Ether (PEGDE) and containing Calcium Hydroxyapatite (CaHA), Glycine and L-Proline subjected to different conditions. Also, a shear rate ramp test was performed in order to investigate the filler's flow behavior. (3) Results and Conclusions: G' (elastic modulus), G'' (viscous modulus) and consequentially tan δ (tangent of the phase angle) show a similar trend at different thermal conditions, underlining that the product is not affected by the storage conditions. The viscosity of the dermal filler decreases with an increasing shear rate, so a non-Newtonian shear thinning pseudoplastic behavior was demonstrated in all tested conditions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9140203 | PMC |
http://dx.doi.org/10.3390/gels8050264 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!