Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis' retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scrutinized clinical records until at least seven years of function. Thirty-six were retained on Locator Abutments (LA) and thirty-tree on Ball Abutments (BA). Both systems were compared regarding the type, amount, and total cost of required maintenance. One implant was lost, yielding 98.7% survival after seven years. In total, 438 technical issues occurred: 121 (27.35%) in BA and 317 (72.4%) in LA. Out of these, 343 events (78%) were solved chairside: 191 (43.6%) were replacements of retention caps, 113 (25.8%) were minor acrylic repairs, 26 (5.9%) pressure ulcers had to be relieved, and 13 (3%) were related to abutments. LA required 179 insert replacements compared to 12 in the BA group. The overall initial treatment cost was EUR 3850 (base year of the analysis: 2003). The average total maintenance cost in relation to the initial cost for the LA and BA groups was 19.11 (range 0-82.24%) and 18.91% (range 0-113.26%) respectively ( = 0.540). Conclusions: The seven-year maintenance costs for a 2IOD is acceptable when the patient is regularly checked and professionally maintained. Most events are easily solvable chairside, but a few patients required more expensive interventions, regardless of the type of attachment used.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9139480 | PMC |
http://dx.doi.org/10.3390/dj10050088 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!