A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic imaging for suspected pulmonary embolism during pregnancy and postpartum: A comparative radiation dose study. | LitMetric

Introduction: To compare the radiation dose exposure and diagnostic efficiency of computed tomographic pulmonary angiography (CTPA) and ventilation/perfusion imaging (V/Q) for clinically suspected pulmonary embolism (PE) in pregnant and postpartum women in a tertiary hospital setting.

Methods: A retrospective cohort study of 473 pregnant and postpartum women referred for CTPA or V/Q for clinically suspected PE between January 2013 and December 2018 at a tertiary hospital. Maternal effective radiation dose, breast-absorbed radiation dose and fetal-absorbed dose estimates were calculated. Diagnostic yield was evaluated from radiological findings.

Results: Computed tomographic pulmonary angiography (CTPA) was more commonly used for the imaging of suspected PE in pregnant and postpartum populations (51.9% vs. 48.1% and 77.1% vs. 22.9%, respectively). CTPA was associated with higher maternal effective and breast-absorbed doses (maternal effective CTPA 4.7 (±2.9) mSv (millisievert), V/Q 1.7(±0.8) mSv (mean difference 2.93 mSv P < 0.001), and breast-absorbed CTPA 8.0 (±5.2) mGy (milligray), V/Q 0.3 (±0.1) (mean difference 7.67 mGy P < 0.001), respectively). Fetal radiation dose exposure was low. The incidence of positive PE was 5.5%. Indeterminate rates of CTPA and V/Q were 3.0% and 5.5% (P = 0.176), respectively.

Conclusions: Compared to V/Q, CTPA is associated with higher maternal and breast radiation dose; however, modern CT scanners achieve lower radiation doses than historically described. Fetal radiation dose was comparably low. The diagnostic yield of the imaging modalities in pregnant and postpartum women is similar. Revision of guidelines should occur with the advances in CT technology.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1754-9485.13420DOI Listing

Publication Analysis

Top Keywords

radiation dose
16
pregnant postpartum
12
maternal effective
12
imaging suspected
8
suspected pulmonary
8
pulmonary embolism
8
computed tomographic
8
tomographic pulmonary
8
pulmonary angiography
8
angiography ctpa
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!