A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Whole-cell electric sensor for determination of sodium dodecyl sulfate. | LitMetric

Whole-cell electric sensor for determination of sodium dodecyl sulfate.

World J Microbiol Biotechnol

Institute of Biochemistry and Physiology of Plants and Microorganisms, Saratov Scientific Centre of the Russian Academy of Sciences (IBPPM RAS), Saratov, 410049, Russia.

Published: May 2022

Linear alkyl sulfates are a major class of surfactants that have large-scale industrial application and thus wide environmental release. These organic pollutants threaten aquatic environments and other environmental compartments. We show the promise of the use of a whole-cell electric sensor in the analysis of low or residual concentrations of sodium dodecyl sulfate (SDS) in aqueous solutions. On the basis of bioinformatic analysis and alkylsulfatase activity determinations, we chose the gram-negative bacterium Herbaspirillum lusitanum, strain P6-12, as the sensing element. Strain P6-12 could utilize 0.01-400 mg/L of SDS as a growth substrate. The electric polarizability of cell suspensions changed at all frequencies used (50-3000 kHz). The determination limit of 0.01 mg/L is much lower than the official requirements for the content of SDS in potable and process water (0.5 and 1.0 mg/L, respectively), and the analysis takes about 1-5 min. The promise of H. lusitanum P6-12 for use in the remediation of SDS-polluted soils is discussed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9132749PMC
http://dx.doi.org/10.1007/s11274-022-03309-1DOI Listing

Publication Analysis

Top Keywords

whole-cell electric
8
electric sensor
8
sodium dodecyl
8
dodecyl sulfate
8
strain p6-12
8
sensor determination
4
determination sodium
4
sulfate linear
4
linear alkyl
4
alkyl sulfates
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!