A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental investigation of transvenous embolization of arteriovenous malformations using different in vivo models. | LitMetric

Background: Transvenous embolization (TVE) is an emerging technique for the endovascular treatment of cerebral arteriovenous malformations (AVMs). The aim of this study was to investigate two in vivo AVM models and to assess TVE techniques using these models.

Methods: Blood flow in the porcine rete mirabile (RM) was modified by either creating a carotid-jugular fistula or by placing a balloon guide catheter in the carotid artery. The RM was embolized with precipitating hydrophobic injectable liquid (PHIL) 25% via transarterial embolization (TAE; control group) and compared with TVE applying the transvenous retrograde pressure cooker technique and TVE using a Woven EndoBridge (WEB) device for flow control (n=6, respectively). The embolization extent (penetration of the RM), the number of events of reflux or embolization distal to the RM and the procedure times were assessed.

Results: The modified RM could be successfully used for embolization in all cases. There were no significant differences regarding the outcome parameters between the two AVM models (fistula or balloon). TVE using the pressure cooker technique led to a higher extent of embolization (median 98.8% vs 63.5%; p=0.008), a lower number of reflux or distal embolization events (p<0.001) and a shorter procedure time (p<0.001) compared with conventional TAE. TVE using a WEB device for flow control was technically feasible and achieved a moderate extent of embolization (median 83.8%).

Conclusion: After surgical or endovascular modification, the porcine RM is a feasible in vivo AVM model for the investigation of TVE techniques. TVE using the pressure cooker technique is superior to conventional TAE in this experimental model.

Download full-text PDF

Source
http://dx.doi.org/10.1136/neurintsurg-2022-018894DOI Listing

Publication Analysis

Top Keywords

embolization
8
transvenous embolization
8
arteriovenous malformations
8
avm models
8
pressure cooker
8
cooker technique
8
tve
5
experimental investigation
4
investigation transvenous
4
embolization arteriovenous
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!