TransDose: a transformer-based UNet model for fast and accurate dose calculation for MR-LINACs.

Phys Med Biol

Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou 510060, People's Republic of China.

Published: June 2022

. To present a transformer-based UNet model (TransDose) for fast and accurate dose calculation for magnetic resonance-linear accelerators (MR-LINACs).. A 2D fluence map from each beam was first projected into a 3D fluence volume and then fed into the TransDose model together with patient density volume and output predicted beam dose. The proposed TransDose model combined a 3D residual UNet with a transformer encoder, where convolutional layers extracted the volumetric spatial features, and the transformer encoder processed the long-range dependencies in a global space. Ninety-eight cases with four tumor sites (brain, nasopharynx, lung, and rectum) treated with fixed-beam intensity-modulated radiotherapy were included in the dataset; 78 cases were used for model training and validation; and 20 cases were used for testing. The ground-truth beam doses were calculated with Monte Carlo (MC) simulations within 1% statistical uncertainty and magnetic field strength = 1.5 T in the superior and inferior direction. Beam angles from the training and validation datasets were rotated 2-5 times, and doses were recalculated to augment the datasets.. The dose-volume histograms and indices between the predicted and MC doses showed good consistency. The average 3D-passing rates (3%/2 mm, for dose regions above 10% of maximum dose) were 99.13 ± 0.89% (brain), 98.31 ± 1.92% (nasopharynx), 98.74 ± 0.70% (lung), and 99.28 ± 0.25% (rectum). The average dose calculation time, which included the fluence projection and model prediction, was less than 310 ms for each beam.. We successfully developed a transformer-based UNet dose calculation model-TransDose in magnetic fields. Its accuracy and efficiency indicated its potential for use in online adaptive plan optimization for MR-LINACs.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ac7376DOI Listing

Publication Analysis

Top Keywords

dose calculation
16
transformer-based unet
12
unet model
8
fast accurate
8
accurate dose
8
transdose model
8
transformer encoder
8
training validation
8
dose
7
model
6

Similar Publications

Importance: Increasing the understanding of vaccine effectiveness (VE) against levels of severe influenza in children could help increase uptake of influenza vaccination and strengthen vaccine policies globally.

Objective: To investigate VE in children by severity of influenza illness.

Design, Setting, And Participants: This case-control study with a test-negative design used data from 8 participating medical centers located in geographically different US states in the New Vaccine Surveillance Network from November 6, 2015, through April 8, 2020.

View Article and Find Full Text PDF

Background: Huntington's disease (HD) is a rare neurodegenerative disorder caused by an expansion of the CAG trinucleotide repeat in the huntingtin gene which encodes the mutant huntingtin protein (mHTT) that is associated with HD-related neuropathophysiology. Noninvasive visualization of mHTT aggregates in the brain, with positron emission tomography (PET), will allow to reliably evaluate the efficacy of therapeutic interventions in HD. This study aimed to assess the radiation burden of [F]CHDI-650, a novel fluorinated mHTT radioligand, in humans based on both in vivo and ex vivo biodistribution in mice and subsequent determination of dosimetry for dosing in humans.

View Article and Find Full Text PDF

Background/objectives: Calculating the radiation dose from CT in F-PET/CT examinations poses a significant challenge. The objective of this study is to develop a deep learning-based automated program that standardizes the measurement of radiation doses.

Methods: The torso CT was segmented into six distinct regions using TotalSegmentator.

View Article and Find Full Text PDF

This research aims to investigate the heavy metals (i.e., Cd, Cr, Cu, Ni, and Pb) in the fruiting bodies of six indigenous wild edible mushrooms including , , , , , and , correlated with various factors, such as the growth substrate, the sampling site, the species and the morphological part (i.

View Article and Find Full Text PDF

Range of Flexion Improvement in Degenerative Stages of the First Metatarsophalangeal Joint () with Cross-Linked Hyaluronic Acid: A Cadaveric Study.

J Funct Morphol Kinesiol

December 2024

Human Anatomy and Embryology Unit, Experimental Pathology and Therapeutics Department, Faculty of Medicine and Health Sciences, University of Barcelona, 08907 Hospitalet, Spain.

Background: Viscosupplementation consists of intraarticular hyaluronic acid injections applied to treat pain and improve joint mobility. The objective of the study was to analyze the improvement of the range of mobility of the first metatarsophalangeal joint with a single dose of cross-linked hyaluronic acid.

Methods: Ten fresh frozen specimens of feet sectioned below the knee were selected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!