A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design and characterization of third-order Sallen-Key digital filter in nuclear signal processing. | LitMetric

The Gaussian filter shaping circuit is widely used in the nuclear pulse signal processing due to its good performance in amplitude extraction and pulse counting. A third-order Sallen-Key (3rd S-K) filter shaping circuit is designed based on a RC integrator and a second-order Sallen-Key (2nd S-K) circuit. According to the digital 3rd S-K, the transfer functions is derived in the Laplacian domain, and the numerical recurrence model is analyzed and researched, the purpose is to obtain its transfer function and amplitude-frequency response curve in the z-domain. For the simulation and actual sampling of the nuclear signal, digital shaping processing is performed at different parameters, three parameters (d, SNR, δ) are defined to compare and analyze the amplitude extraction, noise suppression and symmetry of the digital shaping method, which shows that as the shaping parameters increases, the digital shaping output noise suppression performance is better, the SNR increased from 49.25 to 64.21, the waveform is more symmetrical, the δ reduced from 34.05 to 0.22. At the same parameters, it is compared and analyzed with CR-RC and 2nd S-K shaping methods, according to the digital Gaussian shaping results, the 3rd S-K digital shaping method has better pulse amplitude extraction(d = 36.06%), noise suppression performance (SNR = 64.21) and waveform symmetry (δ = 0.22). Under different shaping methods, the energy resolution and pulse counting rate of the Fe characteristic X-ray energy spectrum are compared based on a Si-PIN detector. The results show that the 3rd S-K digital shaping method has better energy resolution performance and comprehensive performance indicators, which can be further applied for digital shaping of nuclear pulse signals.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2022.110277DOI Listing

Publication Analysis

Top Keywords

digital shaping
24
3rd s-k
16
shaping
12
noise suppression
12
shaping method
12
digital
9
third-order sallen-key
8
nuclear signal
8
signal processing
8
filter shaping
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!