Aims: The 15-year results of the EORTC 229922-10925 phase III trial showed a significant reduction in breast cancer mortality and breast cancer recurrences after internal mammary chain (IMC) and medio-supraclavicular irradiation. Unexpectedly, cardiac death was not increased, and the incidence of cardiac events did not differ between left- and right-sided cases, although target volume coverages and organ at risk doses were unknown. Therefore, a planning study was carried out comparing the past and the present, to eventually enable, thereafter, an increased therapeutic ratio of IMC irradiation.

Materials And Methods: A planning study was carried out on target volume coverage and organ at risk doses for whole-breast irradiation (WBI) ± IMC comparing the results between two-dimensional radiotherapy (free-breathing), hybrid intensity-modulated radiotherapy (IMRT; breath-hold) and robust intensity-modulated proton therapy (IMPT; free-breathing) for 10 left-sided breast cancer cases. Two-dimensional radiotherapy consisted of two tangential wedged photon breast fields and mixed electron/photon beams for the IMC. Hybrid IMRT included two tangential photon breast fields (70%) complemented with IMRT (30%). IMPT plans were created using multi-field robust optimisation (5 mm set-up and 3% range uncertainties) with two (WBI) or three (WBI + IMC) beams.

Results: Target volume dose objectives were met for hybrid IMRT and IMPT. For two-dimensional radiotherapy, target coverage was 97% and 83% for breast and IMC, respectively. The mean heart dose for WBI only was <2 Gy for all techniques. For WBI + IMC, heart doses (mean heart dose, mean left anterior descending region, volume of the heart receiving 5 Gy (V5) were significantly higher for two-dimensional radiotherapy when compared with contemporary techniques. The V5 left anterior descending region reduced from 100% (two-dimensional radiotherapy) to 70% and 20% for hybrid IMRT and IMPT, respectively.

Conclusion: Contemporary radiotherapy techniques result in improved target volume coverage and significantly decreased heart doses for WBI + IMC radiotherapy. Hence, nowadays an increased therapeutic ratio of elective IMC irradiation may be anticipated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clon.2022.04.004DOI Listing

Publication Analysis

Top Keywords

target volume
16
organ risk
12
risk doses
12
breast cancer
12
two-dimensional radiotherapy
12
volume coverage
8
coverage organ
8
whole-breast irradiation
8
internal mammary
8
mammary chain
8

Similar Publications

Background: Angelman syndrome (AS), a severe neurodevelopmental disorder resulting from the loss of the maternal UBE3A gene, is marked by changes in the brain's white matter (WM). The extent of WM abnormalities seems to correlate with the severity of clinical symptoms, but these deficits are still poorly characterized or understood. This study provides the first large-scale measurement of WM volume reduction in children with AS.

View Article and Find Full Text PDF

Dynamic WaveArc (DWA) is a technique used for continuous, non-coplanar volumetric-modulated arc therapy on the Vero4DRT platform. This study aimed to evaluate the application of single-isocenter DWA (SI-DWA) for treating multiple brain metastases by comparing dose distribution and irradiation time with multi-isocenter DWA (MI-DWA) through retrospective treatment planning. Treatment plans were developed for SI-DWA and MI-DWA in 14 cases with 3-5 brain metastases.

View Article and Find Full Text PDF

We assessed the effect of beam size on plan robustness for intensity-modulated proton therapy (IMPT) of head and neck cancer (HNC) and compared the plan quality including robustness with that of intensity-modulated radiation therapy (IMRT). IMPT plans were generated for six HNC patients using six beam sizes (air-sigma 3-17 mm at isocenter for a 70-230 MeV) and two optimization methods for planning target volume-based non-robust optimization (NRO) and clinical target volume (CTV)-based robust optimization (RO). Worst-case dosimetric parameters and plan robustness for CTV and organs-at-risk (OARs) were assessed under different scenarios, assuming a ± 1-5 mm setup error and a ± 3% range error.

View Article and Find Full Text PDF

Microglia membrane-mediated trans-blood-brain barrier prodrug micelles enhance phagocytosis for glioblastoma chemo-immunotherapy.

J Control Release

December 2024

College of Pharmaceutical Science, Zhejiang University, 866 Yuhangtang Road, Hangzhou 310058, China; National Key Laboratory of Advanced Drug Delivery and Release Systems, Zhejiang University, Hangzhou 310058, China. Electronic address:

Glioblastoma-associated macrophages & microglia (GAMs) are critical immune cells within the glioblastoma (GBM) microenvironment. Their phagocytosis of GBM cells is crucial for initiating both innate and adaptive immune responses. GBM cells evade this immune attack by upregulating the anti-phagocytic molecule CD47 on their surface.

View Article and Find Full Text PDF

Radiomics and deep learning models for glioblastoma treatment outcome prediction based on tumor invasion modeling.

Phys Med

December 2024

Division of Medical Radiation Physics, Department of Physics, Stockholm University, Stockholm, Sweden; Department of Oncology-Pathology, Karolinska Institutet, Stockholm, Sweden.

Purpose: We investigate the feasibility of using a biophysically guided approach for delineating the Clinical Target Volume (CTV) in Glioblastoma Multiforme (GBM) by evaluating its impact on the treatment outcomes, specifically Overall Survival (OS) time.

Methods: An established reaction-diffusion model was employed to simulate the spatiotemporal evolution of cancerous regions in T1-MRI images of GBM patients. The effects of the parameters of this model on the simulated tumor borders were quantified and the optimal values were used to estimate the distribution of infiltrative cells (CTVmodel).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!