A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The experience of an indipendent center with the MINIHIP® femoral stem. | LitMetric

The experience of an indipendent center with the MINIHIP® femoral stem.

Acta Biomed

1 Orthopedic and Traumatology Unit, San Bortolo Hospital, Viale Rodolfi 37, 36100, Vicenza, Italy.

Published: March 2022

The implantation of short femoral stems has significantly increased over the past decade, thanks to their preservation of bone stock, allowing for easier potential revision of components and physiological joint reconstruction. Their main features are metaphyseal fixation and partial retention of the femoral neck which lead to biomechanical advantages and high stability. They also guarantee the preservation of bone stock and insertion through minimally invasive approaches. Fifty-one non-consecutive patients with osteoarthritis or avascular necrosis were treated by two senior surgeons with total hip arthroplasty (THA) with anterior or anterolateral approach between April 2013 and October 2016. Cementless short femoral stem monobloc (Minihip, Corin, Cirencester, UK) was implanted in all patients who were studied retrospectively. Radiographic outcome was analyzed and clinical outcomes were assessed with Harris Hip Score (HHS), Hip handicap and Osteaorthritis Outcome Score (HOOS) and Oxford Hip Score (OHS). Based on radiological results we did not find periprosthetic osteolysis while bone resorption was evaluated in 5 implants which were classified according to Gruen. The MiniHip stem demonstrates adequate metaphyseal grip, excellent implant stability to ensure implant survival.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9437677PMC
http://dx.doi.org/10.23750/abm.v92iS3.12559DOI Listing

Publication Analysis

Top Keywords

femoral stem
8
short femoral
8
preservation bone
8
bone stock
8
hip score
8
experience indipendent
4
indipendent center
4
center minihip®
4
femoral
4
minihip® femoral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!